Goodmans ASZ, GSZ, SSX, ASX, DSZ, DSX, GSX, SSZ manual AWUF****1AA

Page 9

PRODUCT IDENTIFICATION

 

Single Piece Air Handlers

 

Model #

Description

 

 

 

 

 

 

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Introducation of

AEPF****16AA

new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and

 

R-410A

 

AEPF****16BA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

introduces new models adding lower kw hit kits on the S&R plate

 

 

 

 

 

AEPF****16BB

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

replaces the current spot welded blower housing with the same cinched or crimped

 

design used on the 80% furnace line.

 

AEPF****16CA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

replaces all ARPFcoils using wavy fin with louver enhanced fin.

 

 

 

 

 

AEPF****1BA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator Introduction of R-

22 Only Air Handlers.

 

 

 

 

 

AEPF313716AA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator (AEPF) and A

Single Piece S Multi-Position EEM motor Painted Flowrator (ASPF). Introduction of

ASPF313716AA

3-Ton Air Handler units with 3-row coil.

 

 

 

 

 

ASPF****16AA

A Single Piece S Multi-Position EEM motor Painted Flowrator. Introduces new

ASPF Air Handlers

 

 

 

 

A Single Piece S Multi-Position EEM motor Painted Flowrator. Revision introuces

ASPF****16BA

modified ASPF control scheme, to ensure blower operation during and after call for

 

heat on units with heat kits and replacing wavy fin with louver enhanced fin on coil

 

 

 

AWUF****1AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers

 

 

 

 

 

 

AWUF****16AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers. All Models will be suitable for use with R-22 and R-

 

410A

 

AWUF3005-101AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers using a Burr Oak Louvered Fin coil.

 

 

 

 

 

AWUF****1BA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Revision replaces

current wavey fin design with new louvered fin design

 

 

 

 

 

AWUF370**16AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduction of

AWUF37 Air Handlers for use with R-22 and R410A.

 

 

 

 

 

AWUF****16BA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision has

 

 

 

 

louver fins & replaces copper tube hairpins with aluminum hairpins.

 

 

 

 

 

ACNF****1AA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release

all models of 13 SEER Dayton uncased air handlers.

 

 

 

 

 

 

 

ACNF****16AA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release

 

 

 

all models of 13 SEER Dayton uncased air handlers.All Models will be suitable for

 

use with R-22 and R-410A

 

ACNF****1BA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision replaces

 

 

 

 

current wavey fin design with new louvered fin design

 

 

 

 

 

AH**-1*

A Single Piece Air Handler Hydronic Air Handler. Revision replaces the time delay

relay in the AH air handlers with the UTEC time delay control board.

 

 

 

9

Image 9
Contents Service Instructions Email us at customerservice@goodmanmfg.com Recognize Safety SYMBOLS, Words and LabelsImportant Information Fax us at 713 Fax us at 931 438Safe Refrigerant Handling Split System Heat Pumps R410A Product IdentificationModel # Description Split System Air Conditioners R410A ASX130**1AA Single Piece Air Handlers AWUF****1AA MBR/MBE Air Handlers Product Identification 1824 3642 ASX13 AccessoriesDSX/SSX16 ASX18 ASZ13 DSZ/SSZ16 ASZ18 Expansion Valve Kits FSK01A Coil Accessories Electric Heat Kitapplications Aruf Electric Heat Kitapplications Aepf Condensing Unit Product DesignFigure a Capacity Control Heating System OperationCooling Cooling CycleHeating Cycle Defrost CycleCooling Cycle System Operation Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting Chart61B ServicingChecking THERMOSTAT, WIRING, and Anticipator Checking Wiring3A Thermostat and Wiring Checking Voltage3C Heating Anticipator 3B Cooling AnticipatorTesting Coil Circuit Checking Time Delay RelayChecking Transformer Control Circuit Checking Cycle ProtectorSingle Phase Testing Compressor ContactorChecking Contactor AND/OR Relays Checking Contactor ContactsTesting FAN Relay Copeland Comfort Alert DiagnosticsDiagnostics Table Checking High Pressure Control Checking Loss of Charge ProtectorChecking LOW Pressure Control Checking Capacitor15A Resistance Check 15B Capacitance CheckRELAY, Start 16B Checking FAN and Blower Motor ECM Motors 16A Checking FAN and Blower Motor Windings PSC MotorsChart on Next Chart from Previous 16C Checking ECM Motor Windings 16D ECM CFM Adjustments MBE / AepfCFM 16E Blower Performance Data 16F Checking GE X13TM MotorsGE X13TM Motor Connections Checking Compressor Testing Compressor Windings17A Resistance Test 17B Ground TestUnloader Test Procedure 17C Unloader Test Procedure17D Operation Test Compressor Ground TestTesting Defrost Control Testing Crankcase Heater Optional ItemTesting Defrost Thermostat Checking Reversing Valve and SolenoidChecking Heater Limit Controls 40 MBR/AR*F Electronic Blower Time Delay RelayChecking Heater Elements Sequence of OperationHeating Operation MBR/AR*F with Single Stage Heat Pumps41 MBE/AEPF with GSX, SSX, ASX, DSX Defrost OperationMBE/AEPF with Single Stage GSX, ASX and SSX Condensers 41A MBE/AEPF with Single Stage GSZ, SSZ, & ASZ Heat Pumps MBE/AEPF with TWO Stage ASX & DSX Condensers Sequence of OperationMBE/AEPF with TWO Stage ASZ & DSZ Heat Pump Units Electric Heater Optional Item 61A Checking Heater Limit Controls 61B Checking Heater Fuse Link Optional Electric HeatersFormulas Refrigeration Repair Practice Leak Testing Nitrogen or NITROGEN-TRACEDEvacuation Brazing MaterialsEvacuation ChargingChecking Compressor Efficiency Final Charge AdjustmentTXV Valves 105B Thermostatic Expansion ValvePressure vs. Temperature Chart 410A Required Liquid Line Temperature Underfeeding OverfeedingSuperheat Checking SubcoolingChecking Expansion Valve Operation 109A TWO Speed ApplicationFixed Orifice Restrictor Devices Subcooling Formula = Sat. Liquid Temp. Liquid LineOvercharge of Refrigerant Checking Restricted Liquid LineNON-CONDENSABLES Compressor BurnoutRefrigerant Piping Accessories for lines greater than 80 feetLong Line SET Application R-410A Tube SizingInstallation Requirements Initial System Charging AIR Handler External StaticCoil Static Pressure Drop Total External StaticStatic Pressure Drop ALL Fuel System AFE18-60A Control Board Accessories Wiring Diagrams10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF