PRODUCT DESIGN
This section gives a basic description of cooling unit opera- tion, its various components and their basic operation. Ensure your system is properly sized for heat gain and loss according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent.
CONDENSING UNIT
The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then dis- charged out of the top of the cabinet. These units are designed for free air discharge, so no additional resistance, like duct work, shall be attached.
The suction and liquid line connections on present models are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit.
GSX, GSZ, ASX, ASZ, SSX, SSZ and DSX, DSZ models are available in 1 1/2 through 5 ton sizes and use
ASX, ASZ, DSX and DSZ
GSX, GSZ, SSX and SSZ
There are a number of design characteristics which are different from the traditional reciprocating and/or scroll com- pressors.
"Ultractech" Series scroll compressors will not have a dis- charge thermostat. Some of the early model scroll compres- sors required discharge thermostat.
"Ultratech" Series scroll compressors use "POE" or polyolester oil which is NOT compatible with mineral oil based lubricants like 3GS. "POE" oil must be used if additional oil is required.
COILS AND BLOWER COILS
MBR/MBE blower cabinets are designed to be used as a two- piece blower and coil combination. MBR/MBE blower sec- tions can be attached to cased evaporator coil. This two- piece arrangement allows for a variety of
It is approved for applications with cooling coils of up to 0.8 inches W.C. external static pressure and includes a feature that allows airflow to be changed by +15%. The MBR blower cabinet uses a PSC motor. It is approved for applications with cooling coils of up to 0.5 inches W.C. external static pres- sure.
The MBR/MBE blower cabinets with proper coil matches can be positioned for upflow, counterflow, horizontal right or horizontal left operation. All units are constructed with
The CAPX/CHPX coils are equipped with a thermostatic expansion valve that has a
The coils are designed for upflow, counterflow or horizontal application, using
25