PRODUCT IDENTIFICATION

 

Single Piece Air Handlers

Model #

 

 

Description

 

 

 

 

 

 

ARUF****16AA

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater Introducation

of new 13 SEER Air Handler Models. All Models will be suitable for use with R-

 

22 and R-410A

 

 

ARUF364216AB

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision

replaces the current spot welded blower housing with the same cinched or

 

crimped design used on the 80% furnace line.

 

 

ARUF486016AB

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision

replaces the current spot welded blower housing with the same cinched or

 

crimped design used on the 80% furnace line.

 

 

ARUF364216AC

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision

replaces the current spot welded blower housing with the same cinched or

 

crimped design used on the 80% furnace line.

 

 

ARUF****16BA

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater. Revision

 

 

 

 

 

replaces all ARUFcoils using wavy fin with louver enhanced fin.

 

 

 

ARUF****1BA

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater Introducation

of R-22 Only Air Handlers.

 

 

 

ARPF****16AA

A Single Piece R Multi-Position PSC Motor Painted Flowrater Introducation of

new 13 SEER Air Handler Models. All Models will be suitable for use with R-22

 

and R-410A

 

 

ARPF364216AB

A Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision

replaces the current spot welded blower housing with the same cinched or

 

crimped design used on the 80% furnace line.

 

 

ARPF486016AB

A Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision

replaces the current spot welded blower housing with the same cinched or

 

crimped design used on the 80% furnace line.

 

 

ARPF****16BA

A Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision

replaces all ARPFcoils using wavy fin with louver enhanced fin.

 

 

 

ARPF****1BA

A Single Piece R Multi-Position PSC Motor Painted Flowrater. Introducation of

R-22 Only Air Handlers.

 

 

 

ADPF****16AA

A Single Piece Downflow PSC Motor Unpainted Flowrater. Introducation of

new 13 SEER Air Handler Models. All Models will be suitable for use with R-22

 

and R-410A

 

 

ADPF364216AB

A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces

the current spot welded blower housing with the same cinched or crimped

 

design used on the 80% furnace line.

 

 

ADPF486016AB

A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces

the current spot welded blower housing with the same cinched or crimped

 

design used on the 80% furnace line.

 

 

ADPF304216AC

A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces

the current spot welded blower housing with the same cinched or crimped

 

design used on the 80% furnace line.

 

 

ADPF****1BA

A Single Piece Downflow PSC Motor Unpainted Flowrater Revision replaces

all ARPFcoils using wavy fin with louver enhanced fin.

 

 

 

 

 

 

 

8

Image 8
Contents Service Instructions Recognize Safety SYMBOLS, Words and Labels Email us at customerservice@goodmanmfg.comImportant Information Fax us at 713 Fax us at 931 438Safe Refrigerant Handling Product Identification Split System Heat Pumps R410AModel # Description Split System Air Conditioners R410A ASX130**1AA Single Piece Air Handlers AWUF****1AA MBR/MBE Air Handlers Product Identification 1824 3642 Accessories ASX13DSX/SSX16 ASX18 ASZ13 DSZ/SSZ16 ASZ18 Expansion Valve Kits FSK01A Coil Accessories Electric Heat Kitapplications Aruf Electric Heat Kitapplications Aepf Product Design Condensing UnitFigure a Capacity Control System Operation HeatingCooling Cooling CycleDefrost Cycle Heating CycleCooling Cycle System Operation AFE18-60A Control Board DescriptionTroubleshooting Chart COOLING/HP Analysis ChartServicing 61BChecking Wiring Checking THERMOSTAT, WIRING, and Anticipator3A Thermostat and Wiring Checking Voltage3B Cooling Anticipator 3C Heating AnticipatorChecking Time Delay Relay Testing Coil CircuitChecking Transformer Control Circuit Checking Cycle ProtectorTesting Compressor Contactor Single PhaseChecking Contactor AND/OR Relays Checking Contactor ContactsCopeland Comfort Alert Diagnostics Testing FAN RelayDiagnostics Table Checking Loss of Charge Protector Checking High Pressure ControlChecking LOW Pressure Control Checking CapacitorRELAY, Start 15A Resistance Check15B Capacitance Check 16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM MotorsChart on Next Chart from Previous 16D ECM CFM Adjustments MBE / Aepf 16C Checking ECM Motor WindingsCFM GE X13TM Motor Connections 16E Blower Performance Data16F Checking GE X13TM Motors Testing Compressor Windings Checking Compressor17A Resistance Test 17B Ground Test17C Unloader Test Procedure Unloader Test Procedure17D Operation Test Compressor Ground TestTesting Crankcase Heater Optional Item Testing Defrost ControlTesting Defrost Thermostat Checking Reversing Valve and Solenoid40 MBR/AR*F Electronic Blower Time Delay Relay Checking Heater Limit ControlsChecking Heater Elements Sequence of OperationMBR/AR*F with Single Stage Heat Pumps Heating OperationMBE/AEPF with Single Stage GSX, ASX and SSX Condensers 41 MBE/AEPF with GSX, SSX, ASX, DSXDefrost Operation 41A MBE/AEPF with Single Stage GSZ, SSZ, & ASZ Heat Pumps Sequence of Operation MBE/AEPF with TWO Stage ASX & DSX CondensersMBE/AEPF with TWO Stage ASZ & DSZ Heat Pump Units Electric Heater Optional Item Formulas 61A Checking Heater Limit Controls61B Checking Heater Fuse Link Optional Electric Heaters Leak Testing Nitrogen or NITROGEN-TRACED Refrigeration Repair PracticeEvacuation Brazing MaterialsCharging EvacuationFinal Charge Adjustment Checking Compressor Efficiency105B Thermostatic Expansion Valve TXV ValvesPressure vs. Temperature Chart 410A Required Liquid Line Temperature Overfeeding UnderfeedingSuperheat Checking Subcooling109A TWO Speed Application Checking Expansion Valve OperationFixed Orifice Restrictor Devices Subcooling Formula = Sat. Liquid Temp. Liquid LineChecking Restricted Liquid Line Overcharge of RefrigerantNON-CONDENSABLES Compressor BurnoutAccessories for lines greater than 80 feet Refrigerant PipingLong Line SET Application R-410A Tube SizingInstallation Requirements AIR Handler External Static Initial System ChargingStatic Pressure Drop Coil Static Pressure DropTotal External Static Accessories Wiring Diagrams ALL Fuel System AFE18-60A Control Board10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF