PRODUCT DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)
| Chlorine | Taste | and | Odor, Particulate | Class | I*; and | against NSF/ANSl | Standard | 53 | for | the reduction of | ||||
(_ | I Tested | and certified | by | NSF International | against | NSF/ANSI Standard | 42 | for | the | reduction of | |||||
| Lead, | Mercury, | Atrazine, | Benzene, | Toxaphene, | Cysts, | Turbidity, | Asbestos, | |||||||
| L ndane, | Tetrach oroethy | ene, Endr | n, A ach or, | Ch | orobenzene, Ethy benzene, TTHM and MTBE. |
This system has been tested according to NSF/ANSl 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl 42/53.
Substance | Reduction | NSF Reduction | Average | Influent | Challenge | Maximum | Average | Minimum | % | Average | % | |||||||||||
Aesthetic | Effects | Requirements | Influent |
| Concentration | Effluent | Effluent | Reduction |
| Reduction | ||||||||||||
Chlorine Taste/Odor | 50% | reduction | 2.0 | mg/L | 2.0 mg/L | _+10% | 0.08 | mg/L | 2.0 | mg/L | 95.93 |
| 97.36 |
| ||||||||
Particulate | Class I* | 85% | reduction | 3533333#/mL | At east 10,000 part c es/mL | 22000 | #/mL** | 11567 | #/mL | 99.38 |
| 99.67 |
| |||||||||
Contaminant |
| NSF Reduction | Average | Influent | Challenge | Maximum | Average | Minimum | % | Average | % | |||||||||||
Reduction |
| Requirements | Influent |
| Concentration | Effluent | Effluent | Reduction |
| Reduction | ||||||||||||
Lead: @ pH 6.5 | 0.010 | mg/L | 150 ug/L | 0.15 | mg/L | _+10% | 1.0 | ug/L | 1 ug/L |
| 99.33 |
| 99.33 |
| ||||||||
Lead: @ pH | 8.5 | 0.010 | mg/L | 157 ug/L | 0.15 | mg/L | _+10% | 2.0 | ug/L | 1.08 | ug/L | 98.72 |
| 99.31 |
| |||||||
Mercury: | @ pH 6.5 | 0.002 | mg/L | 0.0058 | mg/L | 0.006 | mg/L | _+10% | 0.0002 | mg/L | 0.0002 | mg/L | 96.53 |
| 96.53 |
| ||||||
Mercury: | @ pH 8.5 | 0.002 | mg/L | 0.0057 | mg/L | 0.006 | mg/L | _+10% | 0.0002 | mg/L | 0.0002 | mg/L | 96.5 |
| 96.5 |
| ||||||
Benzene |
|
| 0.005 | mg/L | 15 ug/L |
| 0.015 | mg/L | _+10% | 0.5 | ug/L | 0.5 | ug/L | 96.67 |
| 96.67 |
| |||||
0.6 mg/L | 1750 ug/L | 1.8 _+10% |
| 1.0 | ug/L | 1.0 | ug/L | 99.94 |
| 99.94 |
| |||||||||||
Toxaphene |
| 0.003 | mg/L | 15 ug/L |
| 0.015 | _+10% | 1.0 | ug/L | 1.0 ug/L | 93.33 |
| 93.33 |
| ||||||||
Atrazine |
|
| 0.003 | mg/L | 10 ug/L |
| 0.009 | mg/L | _+10% | 2 ug/L |
| 2 ug/L |
| 80.8 |
| 80.8 |
| |||||
Asbestos |
|
| 99% |
| 101 MFL | 107to | 108fibers/L *t | 0.17 | MFL | 0.17 | MFL | 99.83 |
| 99.83 |
| |||||||
Live Cysts* |
| >99.95% | 120,000/L | 50,000/L | min. | 8/12 |
|
| l/L* |
|
| 99.99 |
| >99.99 |
| |||||||
Turbidity |
|
| 0.5 NTU | 11.4 NTU | 11 _+1 NTU | 0.41 | NTU | 0.24 | NTU | 96.4 |
| 97.89 |
| |||||||||
Alachlor |
|
| 0.002 | mg/L | 41.3 | ug/L | 0.04 | _+10% | 0.2 | ug/L | 0.2 ug/L | 99.52 |
| 99.52 |
| |||||||
Endrin |
|
| 0.002 | mg/L | 5.9 | ug/L | 0.006 | _+10% | 0.5 | ug/L | 0.3 | ug/L | 91.5 |
| 95.47 |
| ||||||
Ethylbenzene |
| 0.7 mg/L | 1867 ug/L | 2.1 _+10% |
| 0.70 | ug/L | 0.0588 | ug/L | 99.96 |
| 100 |
| |||||||||
Lindane |
|
| 0.002 | mg/L | 1.9 | ug/L | 0.002 | _+10% | 0.02 | ug/L | 0.02 | ug/L | 98.93 |
| 98.93 |
| ||||||
Chlorobenzene | 0.6 mg/L | 2.0 | ug/L | 2.0 _+10% |
| 0.0005 | ug/L | 0.0005 | ug/L | 99.98 |
| 99.98 |
| |||||||||
Tetrachloroethylene | 0.005 | mg/L | 14.2 ug/L | 0.015 | _+10% | 0.5 | ug/L | 0.5 | ug/L | 96.47 |
| 96.47 |
| |||||||||
TTHM |
|
| 0.080 | mg/L | 465 | ug/L | 0.45 | _+20% | 1.0 | ug/L | 0.5 | ug/L | 99.78 |
| 99.88 |
| ||||||
MTBE |
|
| 0.005 | mg/L | 14 ug/L |
| 0.015 | _+20% | 0.70 | ug/L | 0.52 | ug/L | 94.94 |
| 96.27 |
|
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).
•It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
•Model T1KB1 : The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the filter.
Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.
Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9020. In Canada, use replacement cartridge T1RFKB1, part #9020B. 2005 suggested retail price of $39.99 U.S.A./S59.95 Canada. Prices are subject to change without notice.
•These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
•The product is for cold water use only.
•Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number.
•Refer to the "Warranty" section for the Manufacturer's limited warranty.
| Application | Guidelines/Water | Supply | Parameters | |
Water | Supply | City | or Well |
| |
Water | Pressure | 30 | - 120 | psi | (207 - 827 kPa) |
Water | Temperature | 33 ° - 100°F | (0.6 ° - 37.8°C) | ||
Service | Flow Rate | 0.5 | gpm | (1.9 | L/min) @ 60 psi |
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. tfFibers greater than 10 um in length
*Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
26