Update LEC Operational Parameters 8-9

Example

Enter: [5][3][1] 0

The LEC operational information for the LEC of bridge #0 is displayed as follows:

----------------------------------------------------------

Control Timeout= 120

VCC Timeout= 1200

Aging Time= 300

Forward Delay Time= 15

Expected LE ARP Resp Time= 1

Topology change flag= OFF

Flush Timeout= 4

Path Switching Delay= 6

Connection Completion Timer= 4

----------------------------------------------------------

Figure 8-3LEC Operational Parameters Display

Update LEC

Update the LEC operational parameters: control-timeout,

Operational

VCC-timeout-period, aging-time, forward-delay-time,

Parameters

topology-change-flag, expected LE_ARP response-time, flush-timeout,

 

path-switching-delay and connection-completion-timer. For more

 

information see “LEC Parameters” on page 12-16.

Control-timeoutEnter the bridge number and control-timeout value to update the

 

control-timeout parameter in seconds.

 

 

Table 8-11

Task Actions

 

 

 

 

 

 

 

 

 

 

Menu

 

Enter

Result

 

 

Sequence

 

 

 

 

 

 

 

 

 

 

[5] le

 

1

Bridge Number {0-3}

The control-timeout parameter

 

 

[3] operational

2

Control-timeout {10-300}

is updated for the specified

 

 

[2] control

 

bridge.

 

 

 

 

 

 

 

 

 

 

 

 

Example

Enter: [5][3][2] 0 100

Page 105
Image 105
3Com 7600 manual Update LEC, Update the LEC operational parameters control-timeout, Information see LEC Parameters on