Update LEC Operational Parameters 8-11

Forward-delay-timeEnter the bridge number and forward-delay-time value to update the LEC forward-delay-time parameter.

Table 8-14

Task Actions

 

 

 

 

 

 

 

 

Menu

 

 

 

 

 

Sequence

 

Enter

Result

 

 

 

 

 

 

 

[5] le

 

1

Bridge Number {0-3}

The LEC forward-delay-time

 

[3] operational

2

LEC forward-delay-time

parameter is updated for the

 

[5] forward

 

specified bridge.

 

 

 

{4-30}

 

 

 

 

 

 

 

 

 

 

 

Example

Enter: [5][3][5] 0 20

The forward-delay-time parameter for the LEC of bridge #0 is updated to 20 seconds.

Topology-change-Enter the bridge number and topology-change-flag value to update the flag LEC topology-change-flag parameter.

Table 8-15

Task Actions

 

 

 

 

 

 

 

 

Menu

 

 

 

 

 

Sequence

 

Enter

Result

 

 

 

 

 

 

 

[5] le

 

1

Bridge Number {0-3}

The LEC topology-change-flag

 

[3] operational

2

LEC topology-change-flag

parameter is updated for the

 

[6] topology

specified bridge.

 

 

 

 

 

 

 

 

 

Example

Enter: [5][3][6] 0 ON

The topology-change-flag parameter for the LEC of bridge #0 is updated to ON.

Expected LE_ARP Enter the bridge number and expected LE_ARP response-time value to response-timeupdate the LEC expected LE_ARP response-time parameter.