Image 123

10-4CHAPTER 10: MANAGING SYSTEM FUNCTIONS

Erase Software

Erase the software program from flash prior to downloading of the new

from Flash

system software from a PC or workstation with a VT100 terminal

 

emulation attached directly to the 7600 Card through the emergency

 

serial port.

 

 

 

The software may be loaded without this step.

 

Table 10-4

Task Actions

 

 

 

 

 

 

 

 

Menu

Enter

Result

 

 

Sequence

 

 

 

 

 

 

 

[1] system

None

System software is erased from

 

 

[9] load

 

flash.

 

 

[3] local

 

 

 

 

 

 

 

 

Example

 

 

 

Enter: [1] [9] [3]

 

 

System software is erased from flash.

 

 

 

 

Download

To load a new version of the system software locally, use the following

Software from

procedure:

 

 

Local

 

 

 

 

1Run the terminal emulation program, for example, PROCOMM Plus.

2Pull out the Switch Board from the CELLplex 7000 Switch and leave it out until the procedure is finished.

3Connect the terminal to the internal RS-232 connector located on the right side of the rear-mounted daughter board.

4Reset the unit.

5Press Shift-U. The screen should read “Monitor port = LMA”.

6Change Baud Rate to 57600.

7Press Enter and the prompt (>) appears.

8Type “do” and use the terminal emulation software in binary mode to load the 7600 Fast Ethernet Card software. The name of the 7600 file is 763171.str.