3Com S200 manual Protection Level, Reconnection Timeout, Reconnection Tries Limit

Models: S200

1 85
Download 85 pages 18.3 Kb
Page 22
Image 22
*Protection Level

PAD Port Configuration

*Protection Level

Range:

NONE, CP_ONLY, FULL_DCP

 

 

Default:

NONE

 

 

Description:

Specifies how Data Connection Protection is implemented for this

 

 

port:

 

 

 

• NONE: The feature is turned off.

 

 

 

• CP_ONLY: Connection protection only.

 

 

 

• FULL_DCP: Full data and connection protection.

 

 

Valid only when the Data Connection Protection Option has been

 

 

purchased for this node.

 

 

 

Note

 

 

 

 

 

 

 

 

Changes to this parameter require a Node Boot to take effect.

 

 

 

 

Reconnection Timeout

Range:

1 to 128

 

 

Default:

2

 

 

Description:

• Specifies how many seconds the Data Connection Protection

 

feature waits between reconnection attempts.

 

• The call originator determines the value.

 

If symmetric operation is required, the Reconnection Timeout and

 

the Reconnection Tries limit should be equal.

 

Valid only when the Data Connection Protection Option has been

 

purchased for this node.

 

 

Reconnection Tries Limit

Range:

0 to 127

 

 

Default:

4

 

 

Description:

• Specifies the number of times that the Data Connection

 

Protection feature attempts to reconnect before clearing

 

the call.

 

• The call originator determines the value.

 

If 0 is entered, there will be no attempt to reconnect. If symmetric

 

operation is required, the Reconnection Timeout and the

 

Reconnection Tries limit should be equal.

 

Valid only when the Data Connection Protection Option has been

 

purchased for this node.

 

 

16

Configuring PAD/ATPAD Ports

Page 22
Image 22
3Com S200 manual Protection Level, Reconnection Timeout, Reconnection Tries Limit