3Com S200 Parameter Values Stored In Memory, Parameter Name, Default, Test, Simple, Transpar

Models: S200

1 85
Download 85 pages 18.3 Kb
Page 51
Image 51
Parameter Values Stored In Memory

PAD Profile Table Record

Parameter Values The parameter values for the 14 PAD Profiles are listed in these tables. For example, if you enter 0, you will get all the values listed in the Default column.

Parameter Values Stored In Memory

Parameter Name

Default

Test

Simple

Transpar

CRT

Printer

 

(0)

(1)

(2)

(3)

(4)

(5)

 

 

 

 

 

 

 

#1 PAD Recall

1

1

1

0

1

1

 

 

 

 

 

 

 

#2 Echo

1

1

1

0

1

1

 

 

 

 

 

 

 

#3 Data Forwarding Character

2

2

126

0

2

2

 

 

 

 

 

 

 

#4 Idle Timer Delay

0

0

0

20

0

0

 

 

 

 

 

 

 

#5 Device Flow Control

0

1

1

0

0

2

 

 

 

 

 

 

 

#6 Service Signals Control

5

5

1

0

5

5

 

 

 

 

 

 

 

#7 Break Signal Operation

2

21

2

2

2

21

 

 

 

 

 

 

 

#8 Discard Output

n/a

n/a

n/a

n/a

n/a

n/a

 

 

 

 

 

 

 

#9 Padding After CR

0

0

0

0

0

5

 

 

 

 

 

 

 

#10 Line Folding

0

0

0

0

0

80

 

 

 

 

 

 

 

#11 Speed

n/a

n/a

n/a

n/a

n/a

n/a

 

 

 

 

 

 

 

#12 PAD Data Restraint

1

1

1

0

1

1

 

 

 

 

 

 

 

#13 LF Insertion After CR

4

4

0

0

4

4

 

 

 

 

 

 

 

#14 Padding After LF

0

0

0

0

0

5

 

 

 

 

 

 

 

#15 Editing

1

1

0

0

1

1

 

 

 

 

 

 

 

#16 Character Delete

8

8

8

8

8

8

 

 

 

 

 

 

 

#17 Line Delete

24

24

24

24

24

24

 

 

 

 

 

 

 

#18 Line Display

18

18

18

18

18

18

 

 

 

 

 

 

 

#19 Editing Type

2

1

1

1

2

1

 

 

 

 

 

 

 

#20 Echo Mask

255

0

0

0

255

255

 

 

 

 

 

 

 

#21 Parity Treatment

7

7

7

7

7

7

 

 

 

 

 

 

 

#22 Page Wait

0

0

0

0

0

0

 

 

 

 

 

 

 

#100 Break Character

0

0

0

0

0

0

 

 

 

 

 

 

 

#101 Echo Sub Toggle

0

0

0

0

0

0

Character

 

 

 

 

 

 

 

 

 

 

 

 

 

#102 Echo Sub Character

0

0

0

0

0

0

 

 

 

 

 

 

 

#103 XON Character

17

17

17

17

17

17

 

 

 

 

 

 

 

#104 XOFF Character

19

19

19

19

19

19

 

 

 

 

 

 

 

#105 Data Restraint

0

0

0

0

0

0

 

 

 

 

 

 

 

#106 Network Parity

0

0

0

0

0

0

 

 

 

 

 

 

 

#107 Idle Disconnect Timer

0

0

0

0

0

0

 

 

 

 

 

 

 

#108 Disconnect Character

0

0

0

0

0

0

 

 

 

 

 

 

 

#109 Form Feed Padding

0

40

40

0

0

40

 

 

 

 

 

 

 

#110 ESC Forwarding Delay

0

0

0

0

0

0

 

 

 

 

 

 

 

Configuring PAD/ATPAD Ports

45

Page 51
Image 51
3Com S200 manual Parameter Values Stored In Memory, Parameter Name, Default, Test, Simple, Transpar, Printer