#5, Device Flow Control

PAD Profile Table Record

#5, Device Flow Control

Range:

0 to 2

 

 

Default:

0

 

 

Description:

Specifies if and how the PAD port sending the XON/XOFF

 

 

characters restrains the attached terminal from sending data.

 

 

 

• 0: No control with XON/XOFF.

 

 

 

• 1: Control inbound data from device.

 

 

 

• 2: Control inbound data and PAD commands from device.

 

 

For DRI control using V.24 connector control signals (CTS), set

 

 

this parameter to 0 and use parameter #105, Control Signal

 

 

(EIA-232-D) Data Restraint.

 

 

 

Note

 

 

 

 

 

 

 

 

Called Data Restraint Inbound (DRI) when using inland control.

 

 

 

 

#6, Service Signals Control

Range:

0, 1, 4, 5, 9, 12, 13

 

 

Default:

5

 

 

Description:

Controls PAD service signal messages sent to the attached device:

 

• 0: No service signals sent.

 

• 1: Service signals, other than the prompt, sent.

 

• 4: Prompt service signal sent.

 

• 5: All service signals sent.

 

• 9: Extended format service signals, other than prompt, sent.

 

• 12: Extended format prompt service signal sent.

 

• 13: All service signals sent in extended format.

 

 