3Com S200 manual Port Type, Clock Speed, Parameters, Connection Type

Models: S200

1 85
Download 85 pages 18.3 Kb
Page 69
Image 69
Port Type

 

 

 

ATPAD Ports

Parameters

 

 

 

These tables describe the parameters used to configure the ATPAD port.

 

 

Note

 

 

 

 

 

 

 

 

 

Unless otherwise indicated, a Node Boot must be performed to have changes

 

 

take affect.

 

 

Port Type

 

 

 

 

 

Range:

NULL, PAD, X25, SDLC, FRI, ATPAD, PPP

 

 

 

 

Default:

PAD

 

 

 

 

Description:

Specifies the port type.

 

 

 

• NULL: NULL type port

 

 

 

• PAD: PAD type port

 

 

 

• X25: X25 type port

 

 

 

• SDLC: SDLC hpad/tpad

 

 

 

• FRI: Frame Relay Interface port

 

 

 

• ATPAD: ATPAD type port

 

 

 

• PPP: PPP type port

 

 

 

 

Connection Type

Range:

SIMP, DTR

 

 

Default:

SIMP

 

 

Description:

Specifies the control signal handshaking required for a connection

 

to be made to this port.

 

• SIMP: Simple, no control signals required

 

• DTR: Dedicated, require the data terminal ready signal (DTR)

 

 

Clock Speed

Range:

50, 75, 100, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800,

 

7200, 9600, 19200, 38400, 57600, 115200, 75/1200

 

 

Default:

9600

 

 

Description:

Speed of the port in bits per second, when using internal clocking.

 

 

 

Note

 

 

 

 

 

 

 

 

The maximum port speed is dependent on the type of hardware

 

 

installed.

 

 

 

 

Configuring PAD/ATPAD Ports

63

Page 69
Image 69
3Com S200 manual Port Type, Clock Speed, Parameters, Connection Type