3Com S200 manual XON Character, Escape Sequence Timer, Data Forwarding Timer, Flow Control

Models: S200

1 85
Download 85 pages 18.3 Kb
Page 72
Image 72

ATPAD Ports

XON Character

Range:

0 to 255

 

 

Default:

17

 

 

Description:

Specifies the value of the ASCII character used for the XON

 

function.

 

 

Boot Type:

A Port boot is required for the change to take effect.

 

 

Flow Control

Range:

NONE, CNTL, XOFF

 

 

Default:

NONE

 

 

Description:

Specifies the type of flow control that the port uses:

 

• NONE: No flow control

 

• CNTL: Control signal flow control

 

• XOFF: XON/XOFF flow control

 

 

Boot Type:

A Port boot is required for the change to take effect.

 

 

Escape Sequence Timer

Range:

1 to 51

 

 

Default:

10

 

 

Description:

Value of the escape time in 100- millisecond increments. A value

 

of 10 corresponds to 1 second.

 

 

Boot Type:

A Port boot is required for the change to take effect.

 

 

Data Forwarding Timer

Range:

0 to 255

 

 

Default:

0

 

 

Description:

Selects the forwarding idle timer that determines when data is

 

packetized and sent to the network.

 

• 0: time disabled

 

• 1 to 255: value of idle time in 1/20 seconds

 

 

Boot Type:

A Port boot is required for the change to take effect.

 

 