8 Counting Mode

Counting Mode

In counting mode the total weight of articles is converted to a count and assumes all articles have the same mass value.

It is necessary to store a unit mass to count articles.

8.1 Storing a Unit Mass

Step

1

Press the

MODE

switch to display the unit PCS.

Step

2

Press the

 

switch to enter the mode to store

SET

 

 

a unit mass.

Step

3

Press the ^ switch to select the number of

 

 

samples. The greater the quantity of samples, the

 

 

greater the accuracy of the count. Select from

 

 

5 pieces, 10 pieces, 20 pieces, 50 pieces, 100

 

 

pieces

Step

4

Put the container onto the pan.

 

 

Press the

 

 

switch.

 

 

 

TARE

Step 5 Put in the number of samples selected at step 3. Press the ENTER switch to store the weight after the stability mark is displayed. The count is then displayed.

Caution

When the sample is too light and it is not possible to calculate a unit mass, the scale displays lo ut and returns to step 3. It is necessary to increase the number of samples.

Pressing the ENTER switch after the lo ut .is displayed, the next unit is displayed.

When the unit mass is too light to store, the scale displays lo ut .

Step 4 Remove all items from the pan.

HW-G Instruction Manual Page 21

HW-G OZIM v1a

Page 23
Image 23