9 Percentage Mode

The percentage mode is to display a mass value in the unit of “%”.

It is necessary to store a 100% mass value in advance to use this function.

9.1 Storing a 100% Mass

Step 1 Press the MODE switch to display the unit %.

Step 2 Press the SET switch to enter the mode that stores a 100% mass.

Step 3 If necessary, with nothing on the pan press the ZERO switch to display zero.

Step 4 Gently place the 100% mass onto the pan. Press the ENTER switch to store the mass after the stability mark is displayed. Then the percentage unit is displayed.

Caution

When the sample is too light and it is not possible to calculate a 100% mass, the scale displays lo . and returns to step 3.

Pressing the ENTER switch after lo is displayed, the next unit is displayed.

Step 5 Remove all items from the pan.