Command Line Interface

exec-timeout

This command sets the interval that the system waits until user input is detected. Use the no form to restore the default.

Syntax

exec-timeout [seconds] no exec-timeout

seconds - Integer that specifies the number of seconds. (Range: 0 - 65535 seconds; 0: no timeout)

Default Setting

CLI: No timeout

Telnet: 10 minutes

Command Mode

Line Configuration

Command Usage

If user input is detected within the timeout interval, the session is kept open; otherwise the session is terminated.

This command applies to both the local console and Telnet connections.

The timeout for Telnet cannot be disabled.

Example

To set the timeout to two minutes, enter this command:

Console(config-line)#exec-timeout 120

Console(config-line)#

password-thresh

This command sets the password intrusion threshold which limits the number of failed logon attempts. Use the no form to remove the threshold value.

Syntax

password-thresh threshold no password-thresh

threshold - The number of allowed password attempts. (Range: 1-120; 0: no threshold)

Default Setting

The default value is three attempts.

Command Mode

Line Configuration

4-12

Page 158
Image 158
Accton Technology VS4512DC manual Password-thresh, Syntax Exec-timeout seconds no exec-timeout

VS4512DC, VS4512 specifications

Accton Technology is renowned for its innovative networking solutions and has made significant strides in the realm of networking devices with its VS4512 and VS4512DC models. These devices cater primarily to the advanced needs of enterprise and data center environments, providing robust features and cutting-edge technologies that enhance network performance and reliability.

The Accton VS4512 is a high-performance Layer 2+ switch designed for top-of-rack applications in data centers. It boasts a compact 1U design, making it highly efficient for space-constrained environments. One of its standout features is the support for Ethernet Flow Control, which significantly reduces data loss during peak traffic loads. This is essential for businesses that rely on real-time data processing and streaming.

In terms of scalability, the VS4512 supports up to 48 Gigabit Ethernet ports, which can be expanded using four 10 Gigabit SFP+ uplink ports. This flexibility allows enterprises to customize their network architecture to meet their growing demands, whether they are scaling up for more users or enhancing service capabilities.

The VS4512DC, on the other hand, is the DC version tailored for data centers. It offers similar features as the VS4512 but includes enhancements for power efficiency and redundancy, ensuring that operations can continue smoothly even in power outage scenarios. The VS4512DC features dual power supplies and advanced thermal management, allowing for improved heat dissipation and lower operational costs.

Both models support advanced Layer 3 routing capabilities, enabling efficient traffic management across complex networks. They also incorporate features like VLAN segmentation and link aggregation, which facilitate better bandwidth utilization and improved network security.

Security is another cornerstone of these switches, with features such as DHCP snooping, port security, and storm control to mitigate risks associated with unauthorized access and network congestion.

In summary, the Accton Technology VS4512 and VS4512DC switches represent significant advancements in networking technology, equipped with a comprehensive set of features tailored for modern enterprise needs. With their scalability, robust performance, and focus on security, these switches are positioned to meet the challenges of today's fast-paced digital environments, making them a preferred choice for organizations aiming to enhance their network infrastructure.