Example

Console(config)#snmp-server location WC-19

Console(config)#

Related Commands

snmp-server contact (4-77)

snmp-server host

This command specifies the recipient of a Simple Network Management Protocol notification operation. Use the no form to remove the specified host.

Syntax

snmp-server host host-addrcommunity-string[version {1 2c}] no snmp-server host host-addr

host-addr- Internet address of the host (the targeted recipient). (Maximum host addresses: 5 trap destination IP address entries)

community-string- Password-like community string sent with the notification operation. Although you can set this string using the snmp-server host command by itself, we recommend that you define this string using the snmp-server community command prior to using the snmp-server host command. (Maximum length: 32 characters)

version - Specifies whether to send notifications as SNMP v1 or v2c traps.

Default Setting

Host Address: None

SNMP Version: 1

Command Mode

Global Configuration

Command Usage

If you do not enter an snmp-server host command, no notifications are sent. In order to configure the switch to send SNMP notifications, you must enter at least one snmp-server host command. In order to enable multiple hosts, you must issue a separate snmp-server host command for each host.

The snmp-server host command is used in conjunction with the snmp-server enable traps command. Use the snmp-server enable traps command to specify which SNMP notifications are sent globally. For a host to receive notifications, at least one snmp-server enable traps command and the snmp-server host command for that host must be enabled.

Some notification types cannot be controlled with the snmp-server enable traps command. For example, some notification types are always enabled.

The switch can send SNMP version 1 or version 2c notifications to a host IP address, depending on the SNMP version that the management station supports. If the snmp-server host command does not specify the SNMP version, the default is to send SNMP version 1 notifications.

4-78

Page 224
Image 224
Accton Technology VS4512DC manual Snmp-server host

VS4512DC, VS4512 specifications

Accton Technology is renowned for its innovative networking solutions and has made significant strides in the realm of networking devices with its VS4512 and VS4512DC models. These devices cater primarily to the advanced needs of enterprise and data center environments, providing robust features and cutting-edge technologies that enhance network performance and reliability.

The Accton VS4512 is a high-performance Layer 2+ switch designed for top-of-rack applications in data centers. It boasts a compact 1U design, making it highly efficient for space-constrained environments. One of its standout features is the support for Ethernet Flow Control, which significantly reduces data loss during peak traffic loads. This is essential for businesses that rely on real-time data processing and streaming.

In terms of scalability, the VS4512 supports up to 48 Gigabit Ethernet ports, which can be expanded using four 10 Gigabit SFP+ uplink ports. This flexibility allows enterprises to customize their network architecture to meet their growing demands, whether they are scaling up for more users or enhancing service capabilities.

The VS4512DC, on the other hand, is the DC version tailored for data centers. It offers similar features as the VS4512 but includes enhancements for power efficiency and redundancy, ensuring that operations can continue smoothly even in power outage scenarios. The VS4512DC features dual power supplies and advanced thermal management, allowing for improved heat dissipation and lower operational costs.

Both models support advanced Layer 3 routing capabilities, enabling efficient traffic management across complex networks. They also incorporate features like VLAN segmentation and link aggregation, which facilitate better bandwidth utilization and improved network security.

Security is another cornerstone of these switches, with features such as DHCP snooping, port security, and storm control to mitigate risks associated with unauthorized access and network congestion.

In summary, the Accton Technology VS4512 and VS4512DC switches represent significant advancements in networking technology, equipped with a comprehensive set of features tailored for modern enterprise needs. With their scalability, robust performance, and focus on security, these switches are positioned to meet the challenges of today's fast-paced digital environments, making them a preferred choice for organizations aiming to enhance their network infrastructure.