Command Line Interface
efm interleave
This command sets the interleave parameters for the selected VDSL port.
Syntax
efm interleave [downstream M value] [upstream M value] [downstream I value] [upstream I value]
no efm interleave
•M value – M is the interleaving depth index. Range:
•I value – I is the interleaving block length. Range: 4 or 8
Default Setting
•M – The interleaving depth index.
Upstream default value: 8, Downstream default value: 16
•I – The interleaving block length.
Upstream default value: 8, Downstream default value: 8
Command Mode
Interface Configuration
Command Usage
Interleaving improves Reed Solomon error correction when there is pulse noise. A greater degree of interleaving will provide more protection against pulse noise but will increase transmission delay and reduce the effective bandwidth of the link. The degree of interleaving can be increased by increasing M or I.
Example
The following example configures VDSL port 1 with:
•M - downstream value: 16, Upstream value: 8
•I - downstream value: 8, Upstream value: 8
Console#config |
|
|
|
|
|
|
|
Console(config)#interface ethernet 1/1 |
|
|
|
|
| ||
|
|
|
|
| |||
|
|
|
|
| |||
Console#show controllers efm status link Ethernet 1/1 |
|
|
| ||||
Interface | Link | SNR (dB) | RS Errs |
| Interleaver |
| |
|
| DS1 DS2 US1 US2 |
| DS.M DS.I US.M US.I PBO | |||
Ethernet 1/1 | Up | 43.0 35.0 45.0 43.0 | 0 | 16 | 8 | 8 | 8 on |
Console# |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Related Commands
efm
show controllers efm status