Accton Technology VS4512 Vdsl Port Link Status, Command Attributes General Status, PMD1 Status

Models: VS4512DC VS4512

1 334
Download 334 pages 13.79 Kb
Page 91
Image 91

 

VDSL Configuration

The following example shows rate adaption enabled for port 1.

 

 

 

Console#config

 

Console(config)#interface ethernet 1/1

4-84

Console(config-if)#efm rate-adapt

4-108

Console(config-if)#end

 

Console#

 

 

 

The following example configures VDSL port 1 with an upstream noise margin of 6, and a downstream noise margin of 6.

Console#config

 

Console(config)#interface ethernet 1/1

4-84

Console(config-if)#efm noise-margin 6 6

4-107

Console(config-if)#end

 

Console#

 

 

 

The following example configures VDSL port 1 with:

M - downstream value: 16, Upstream value: 8

I - downstream value: 8, Upstream value: 8

Console#config

 

 

 

 

 

 

 

Console(config)#interface ethernet 1/1

 

 

 

 

4-84

Console(config-if)#efm interleave 16 8 8 8

 

 

 

 

4-106

Console(config-if)#end

 

 

 

 

 

Console#show controllers efm status link Ethernet 1/1

 

 

 

Interface

Link

SNR (dB)

RS Errs

 

Interleaver

 

 

 

DS1 DS2 US1 US2

 

DS.M DS.I US.M US.I PBO

-------------

----

-------------------- -------- ------------------- ---

Ethernet 1/1

Up

43.0 35.0 45.0 43.0

0

16

8

8

8 on

Console#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDSL Port Link Status

Command Attributes

General Status

-Link – Shows the status of the VDSL link.

-Noise Margin – To ensure a stable link, you should add a margin to the theoretical minimum Signal-to-noise ratio (SNR). For details see “VDSL Port Configuration” on page 3-58.

Range: 0-9 dBm. Default: 0 dBm

PMD1 Status

-SNR (dB) –The signal-to-noise ratio of the VDSL line.

-Downstream Rate (Mbps) – The rate at which data is transmitted from the switch to the CPE.

-Upstream Rate (Mbps) – The rate at which data is transmitted from the CPE to the switch.

1 Physical Media Dependent

3-61

Page 91
Image 91
Accton Technology VS4512DC manual Vdsl Port Link Status, Command Attributes General Status, PMD1 Status