Chapter 2. Installation

Slots 3-5

Slots 3-5 will accept any interface type except second-

 

ary interface, the interface for DTE timing, or the mul-

 

tiport DBU. If other interfaces have any restriction on

 

their location, this will be specified in the individual

 

option card manual (provided with the option cards).

Slot 6

Slot 6 services any option module type including sec-

 

ondary network interface ports (DSX-1 (PBX) and Full

 

D&I), but not the DTE timing source. If a secondary

 

network interface port is to be used, it must be

 

installed in slot 6.

You can use NxDBU modules in any slot.

Power-up Testing

When shipped from the factory, the TSU 600 is set to factory default con- ditions. At the first application of power, the unit automatically exe- cutes a memory self-test. A full self-test can be run from the front panel, and a passcode and unit ID may be set using the UTIL menu.

Self-Test

Upon a power-up, the LCD displays Memory Test Now Testing and the Test LEDs are illuminated.

When . . .

Then . . .

 

 

the self-test is complete

the OK LED lights up and the LCD

with no failures detected

momentarily displays All Tests

 

Passed.

 

 

a failure is detected

a list of failures is displayed in the

 

LCD window

 

 