Chapter 5. Configuration Menu

DTE Timing

The DTE is the source of timing. The TSU 600 uses the incoming DTE clock to determine the transmission timing. This is typically used in ap- plications where it is necessary to have the DTE as the primary clock source (such as limited distance line drivers). See Figure 5-3.

The DTE source timing is restricted from use when a secondary interface is used at the same time.

Clock

NETWORK

1

2

3

4

5

INTERFACE

6

OPTION SLOTS

TIMING SOURCE

 

DTE

 

Figure 5-3.DTE Timed Clock Source

U-BR1TE (Slot 1)

The timing mode selection U-BR1TE (Slot 1) works much like DTE tim- ing except that the clock is derived from the U interface.

61202076L1-1

TSU 600 User Manual

5-5

Page 65
Image 65
ADTRAN 1202076L2#DC, 1202076L1#DC user manual DTE Timing, DTE Timed Clock Source BR1TE Slot