ADTRAN ISU 2X64 user manual = Bisync

Models: ISU 2X64

1 165
Download 165 pages 50.22 Kb
Page 127
Image 127

 

 

Appendix D: S-Register List

S41.......BOND TXFA

Specifies the number of seconds both endpoints at-

 

tempt to detect the BONDING frame pattern when a

 

call is connected before deciding the BONDING call

 

has failed. When operating with other manufacturer's

 

BONDING equipment, it may be necessary to length-

 

en this timer to match TXADD01.

 

0 to 256, 10 sec is default

S42.......BOND TXADD01

The number of seconds both endpoints waits for the

 

additional call to be connected at the end of negotia-

 

tion before determining the BONDING call has failed.

 

When dialing overseas it may be necessary to length-

 

en this timer to allow for lower call routing.

 

0 to 256, 50 sec is default.

S43.......BOND TXDEQ

The number of seconds both endpoints attempt to

 

equalize the network delay between the bearer chan-

 

nels before determining the BONDING call has failed.

 

0 to 256, 5 sec is default.

S44 ........BOND TANULL

The number of seconds the answering endpoint at-

 

tempts to detect the BONDING negotiation pattern

 

from the originating endpoint before aborting to clear

 

channel mode. It may be necessary to shorten this

 

timer if the DTE equipment connected to the ISU 2x64

 

also has timer constraints for completing non-BOND-

 

ING parameter negotiation.

 

0 to 256, 10 sec is default.

S45.......BOND TCID

The number of seconds both endpoints attempt to ne-

 

gotiate agreeable values for bearer channels and chan-

 

nel capacities before determining the BONDING call

 

has failed.

 

0 to 256, 5 sec is default.

S46.......V25 MODE

Selects the type of V.25 bis dialing used.

 

0

= Asynchronous V.25

 

1

= HDLC V.25

 

2

= BISYNC V.25

61200051L1-1D

ISU 2x64 Dual Port ISDN Service Unit User Manual

113

Page 127