Chapter 6. Configuration
When originating calls to unknown units, the ISU begins its pro- tocol selection based on its local Call Type. (Data 64k is used for FALLBACK when selected from the Quick Setup menu.) Upon connection at 64k Call Type, BONDING, V.120, and PPP are attempted. If connection is not made at 64k, the ISU attempts another call at 56k Call Type. If the protocol cannot be negoti- ated, the ISU hangs up the call.
PPPprovides a standard method for transporting
The asynchronous control character map (ACCM) option is scanned during the negotiation. When the ACCM option is seen in a configure ACK link control packet, it is adopted by the ISU 2x64. In addition, when the ACCM option is not seen in the con-
3=CONFIG
1=Clear Channel
| 1=Netw. options | 2=BONDING mode 1 |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
| 2=DTE options | 3=V.120 |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 3=Protocol | 4=V.110 |
|
|
| ||||||
| 4=Quick setup |
|
| 5=DSU 57.6 ASYNC |
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
| 5=Security |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
| 6=Remote Config |
| 7=SAP |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| 8=FALLBACK |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 9=PPP |
|
| 1=PPP | |
|
|
|
|
|
|
|
|
|
| 2=Multilink PPP | |
|
|
|
|
|
|
|
|
|
| 3=PPP w/Comp |
|
|
|
|
|
|
|
|
|
|
| Figure | |
|
|
|
|
|
|
|
|
|
| PPP Menu Tree |
ISU 2x64 Dual Port ISDN Service Unit User Manual | 61 |