Chapter 6. Configuration
3=CONFIG
1=Netw. options
2=DTE options
3=Protocol
4=Quick setup
5=Security
6=Remote Config
1=Clear Channel
2=BONDING mode 1
3=V.120
4=V.110
5=DSU 57.6 ASYNC
7=SAP
8=FALLBACK
9=PPP
1=TXINIT
2=TXFA
3=TXADD01
4=TXDEQ
5=TANULL
6=TCID
7= Async. Rev.
Figure
Protocol BONDING, Mode 1 Menu Tree
The timers are defined as follows:
TXINIT
This option specifies the length of time the originating endpoint attempts to detect BONDING negotiation pattern from the answering endpoint before determining the BONDING call has failed. In general, this timer value should be left at the factory default setting of 10 seconds. Select from values of 1, 2, 5, 10 (default), 20, 50, 100, and 200 seconds.
TXFA
This option specifies the length of time both endpoints attempt to detect the BONDING frame pattern when a call is connected before determining the BONDING call has failed. This timer value should be left at the factory default setting of 10 seconds. However, when interoperating with other manufacturers’ BONDING equipment it may be necessary to lengthen this timer to match TXADD01. Values of 1, 2, 5, 10 (default), 20, 50, 100, and 200 seconds may be selected.
TXADD01
This option specifies the length of time both endpoints wait for the additional call to be connected at the end of negotiation before determining the BONDING call has failed. The factory default setting of 20 seconds is sufficient for most calls to go through, although when dialing overseas it may be necessary to lengthen this timer to allow for slower call routing. Values of 1, 2, 5, 10, 20, 50 (default), 100, and 200 seconds may be selected.