Chapter 10. Troubleshooting
To isolate the problem, use the following procedure:
A.Ensure the ISU 2x64 is set up for the correct switch type.
B.Ensure the quality of the line is satisfactory by checking for near- and
C.Try another piece of functioning ISDN equipment on the ISDN line.
D.With the ISU 2x64 connected to the ISDN line and pow- ered up, talk to the service provider’s repair group and tell them you have an ISDN basic rate line that appears physically okay but has no terminal endpoint identifier (TEI). Ask them to check the line translation and ensure that the line supports dynamic TEI allocation. If using the ISU 2x64 part number 1200051L1 or 1200051L3 with the
5.If the ISU 2x64 continuously reads Register SPID #1,the ISU 2x64 is physically connected to the local telephone service provider and has established logical layer 2. The ISU 2x64 is unable to establish layer 3. The problem is in one or both of the following places:
•The ISU 2x64 software setup
•The telephone service provider’s software setup
To isolate the problem, perform the following procedure:
A.Ensure the ISU 2x64 is set up for the correct switch type.
B.Ensure the ISDN line is multipoint.
C.Ensure that the ISU 2x64 is set up with the correct SPIDs and LDNs.
D.Try another piece of functioning ISDN equipment on the ISDN line.
80 | ISU 2x64 Dual Port ISDN Service Unit User Manual |