User’s Guide
Agilent 34970A Data Acquistion/Switch Unit
Page
 Flexible Data Acquisition/Switching Features
Convenient Data Logging Features
 Front Panel at a Glance
 Front-Panel Menus at a Glance
 Adrs
Display Annunciators
 Use the Menu to
Rear Panel at a Glance
 BenchLink Data Logger Software at a Glance
 Plug-In Modules at a Glance
For detailed information and a module diagram, see
34901A 20-Channel Armature Multiplexer
34902A 16-Channel Reed Multiplexer
 34904A 4x8 Two-Wire Matrix Switch
34903A 20-Channel Actuator/General-Purpose Switch
34905/6A Dual 4-Channel RF Multiplexers
 34907A Multifunction Module
For detailed information and module block diagrams, see
34908A 40-Channel Single-Ended Multiplexer
 This Book
 Contents
 Contents
 Remote Interface Reference
 Application Programs
 Quick Start
 Quick Start
 To Prepare the Instrument for Use
Connect the power cord and turn on the instrument
To Prepare the Instrument for Use
Check the list of supplied items
 Installation Procedure
Installing BenchLink Data Logger Software
Installing BenchLink Data Logger Software
 On-Line Help System
Creating Installation Floppy Disks
 To Connect Wiring to a Module
To Connect Wiring to a Module
 Wire Ohms / RTD
Wire Ohms / RTD / Thermistor
Thermocouple DC Voltage / AC Voltage / Frequency
DC Current / AC Current
 To Set the Time and Date
To Set the Time and Date
Set the time of day
Set the date
 To Configure a Channel for Scanning
To Configure a Channel for Scanning
Select the channel to be added to the scan list
Select the measurement parameters for the selected channel
 View the data from the scan
Run the scan and store the readings in non-volatile memory
 To Copy a Channel Configuration
To Copy a Channel Configuration
 To Close a Channel
To Close a Channel
Select the channel
Close the selected channel Open the selected channel
 Verify the power-line voltage setting
Verify that there is ac power to the instrument
Verify that the power-line fuse is good
If the Instrument Does Not Turn On
 Replace the fuse-holder assembly in the rear panel
 To Adjust the Carrying Handle
To Adjust the Carrying Handle
Bench-top viewing positions
 To Rack Mount the Instrument
To Rack Mount the Instrument
 Quick Start
Page
 Front-Panel Overview
 Front-Panel Overview
 Front-Panel Menu Reference
Front-Panel Menu Reference
 Configure system-related instrument parameters
 To disable monitoring, press again
Enable monitoring on the selected channel
To Monitor a Single Channel
To Monitor a Single Channel
 To Set a Scan Interval
Select the interval scan mode
To Set a Scan Interval
Select the scan count
 To Apply Mx+B Scaling to Measurements
To Apply Mx+B Scaling to Measurements
 To Configure Alarm Limits
To Configure Alarm Limits
Select which of the four alarms you want to use
Select the alarm mode on the selected channel
 Set the limit value
 To Read a Digital Input Port
To Read a Digital Input Port
Select the Digital Input port
Read the specified port
 To Write to a Digital Output Port
To Write to a Digital Output Port
 To Read the Totalizer Count
Configure the totalize mode
To Read the Totalizer Count
Select the totalizer channel
 To Output a DC Voltage
To Output a DC Voltage
Select a DAC Output channel
Output the voltage from the selected DAC
 To Configure the Remote Interface
To Configure the Remote Interface
Select the Gpib Hpib interface
Select the Gpib address
 Select the parity and number of data bits
Select the RS-232 interface Select the baud rate
Select the flow control method
Save the changes and exit the menu
 To Store the Instrument State
To Store the Instrument State
Select the storage location
Store the instrument state
 System Overview
 Control Output, starting on
Data Acquisition System Overview
 Data Acquisition System Overview
Computer and Interface Cable
Advantages Disadvantages
 Agilent BenchLink Data Logger
Measurement Software
 34970A Data Acquisition / Switch Unit
 Plug-In Modules
Signal Routing
Model Number Module Name Common Uses
 System Cabling and Connections starting on
System Cabling
Cable Type Common Uses Comments
 Transducers and Sensors
Alarm Limits
 Switching Topologies
Signal Routing and Switching
Signal Routing and Switching
 Multiplexers are available in several types
 Channel Open
 Internal DMM
Measurement Input
Measurement Input
 Measurement Input
 Scanning
 Scan Count
 Scanning With External Instruments
 Multifunction Module
 +IN
 Control Output
Control Output
 DAC
 Actuator / General-Purpose Switch
Page
 Features and Functions
 Scanning, starting on
Mx+B Scaling, starting on Alarm Limits, starting on
 Scpi Language Conventions
Rules for Using a Channel List
Scpi Language Conventions
 Rules for Scanning
Scanning
Scanning
 Scanning
 Or disable it see Internal DMM Disable on
 Power Failure
 To Build a Scan List From the Front Panel
Adding Channels to a Scan List
 To Build a Scan List From the Remote Interface
 Scan Interval
 See Scan Count on page 86 for more information
Select the interval timer configuration
Set the scan interval to 5 seconds
Sweep the scan list 2 times
 Front-Panel Operation
Select the bus once configuration
Group Execute Trigger
 Select the external trigger configuration
Ext Trig Connector
 On page 86 for more information
 Enable the upper limit
Select the alarm configuration
Report alarms on Alarm
Enable monitoring
 Remote Interface Operation
Scan Count
 Reading Format
 Channel Delay
 Integration Time Channel Delay
Automatic Channel Delays
Range Channel Delay
AC Filter Channel Delay
 Viewing Readings Stored in Memory
 Readings
 Time minimum was logged
Minimum reading on channel
Maximum reading on channel
Time maximum was logged
 Single-Channel Monitoring
Single-Channel Monitoring
 ROUTMONDATA?
 Scanning With External Instruments
Scanning With External Instruments
 Scanning With External Instruments
 Select the channel advance source
Select the scan interval
 General Measurement Configuration
General Measurement Configuration
Measurement Range
 MV Range
 Measurement Resolution
 Integration Time, on page 103 for more information
 102
 PLC
Custom A/D Integration Time
 104
 Autozero
 Temperature Measurement Configuration
Temperature Measurement Configuration
Measurement Units
 Thermocouple Measurements
 108
 Remote Interface Operation You can use the MEASure? or
 To connect an RTD to the module’s screw terminals, see
RTD Measurements
 111
 To connect a thermistor to the module’s screw terminals, see
Thermistor Measurements
 Voltage Measurement Configuration
Voltage Measurement Configuration
DC Input Resistance
Applies to dc voltage measurements only
 Applies to ac voltage and ac current measurements only
AC Low Frequency Filter
Sensvoltacband 3,@203 Select the slow filter 3 Hz
 Resistance Measurement Configuration
Resistance Measurement Configuration
Offset Compensation
To connect resistances to the module’s screw terminals, see
 Current Measurement Configuration
Current Measurement Configuration
Applies to ac current and ac voltage measurements only
 Senscurracband 3,@221 Select the slow filter 3 Hz
 Low Frequency Timeout
Frequency Measurement Configuration
Frequency Measurement Configuration
Sensfreqranglow 3,@203 Select the slow timeout 3 Hz
 Mx+B Scaling
Mx+B Scaling
 = − GF x R
 121
 Alarm Limits
Alarm Limits
 Alarm Limits
 Alarm Event No Alarm Upper Limit Lower Limit
 Then, choose from the following alarm conditions
 Viewing Stored Alarm Data
 127
 Alarms Connector
Using the Alarm Output Lines
 Clear all four alarm outputs
Clear alarm output line
 Using Alarms With the Multifunction Module
 Following commands also see the example on the following
 Calccompmask command decimal
Calccompdata command decimal
Result no alarm generated
Data read from port decimal
 Digital Input Operations
Digital Input Operations
 Read both ports together
Read port
Add port 02 read to scan list
 Totalizer Operations
Totalizer Operations
 136
 137
 Digital Output Operations
Digital Output Operations
Write to port
Write to both ports
 DAC Output Operations
DAC Output Operations
Three slots six DAC channels
 State Storage
System-Related Operations
System-Related Operations
 141
 Error Conditions
 Returns 0 if the self-test is successful or 1 if it fails
Self-Test
 Display Control
 Real-Time System Clock
Internal DMM Disable
Set time to 345 PM
Set date to June 1
 HEWLETT-PACKARD,34970A,0,X.X-Y.Y-Z.Z
Firmware Revision Query
 Relay Cycle Count
 148
 You cannot query the Scpi version from the front panel
Scpi Language Version Query
 Remote Interface Configuration
Remote Interface Configuration
Gpib Address
You can set the Gpib address from the front panel only
 Remote Interface Selection
 Parity Selection RS-232
Baud Rate Selection RS-232
You can set the baud rate from the front panel only
You can set the parity from the front panel only
 Flow Control Selection RS-232
 154
 Calibration Security
Calibration Overview
Calibration Overview
 156
 Enter new code
Unsecure with old code
 Calibration Message
 Calibration Count
 Factory Reset State
Factory Reset State
 Instrument Preset State
Instrument Preset State
 Multiplexer Module Default Settings
Multiplexer Module Default Settings
 Module Overview
Module Overview
 34901A 20-Channel Multiplexer
34901A 20-Channel Multiplexer
 Name Function Comments
Slot Number
 34902A 16-Channel Multiplexer
34902A 16-Channel Multiplexer
 167
 34903A 20-Channel Actuator
34903A 20-Channel Actuator
 169
 34904A 4x8 Matrix Switch
34904A 4x8 Matrix Switch
 Name Comments
 34905A/6A Dual 4-Channel RF Multiplexers
34905A/6A Dual 4-Channel RF Multiplexers
 173
 Digital Input/Output
34907A Multifunction Module
Totalize Input
Analog Output DAC
 Digital Input / Output
Slot Number 100 200
Totalizer
DAC Output
 34908A 40-Channel Single-Ended Multiplexer
34908A 40-Channel Single-Ended Multiplexer
 177
 178
 Remote Interface Reference
 Calibration Commands, starting on
Totalizer Commands, starting on
Scanning Overview, starting on
 Scpi Command Summary
Scpi Command Summary
 Rules for Using scanlist and chlist Parameters
 Monitor Commands
Scpi Command Summary Scan Measurement Commands
See page 226 for more information
See page 237 for more information
 FORMat
Scpi Command Summary Scan Configuration Commands
 Scan Memory Commands
Scpi Command Summary Scan Statistics Commands
See page 233 for more information
See page 235 for more information
 See page 239 for more information
Scpi Command Summary Scanning With an External Instrument
 See page 219 for more information
Scpi Command Summary Temperature Configuration Commands
 See page 223 for more information
Scpi Command Summary Voltage Configuration Commands
 See page 224 for more information
Scpi Command Summary Resistance Configuration Commands
 Scpi Command Summary Current Configuration Commands
 See page 214 for more information
 See page 244 for more information
Scpi Command Summary Mx+B Scaling Commands
 See page 247 for more information
Scpi Command Summary Alarm Limit Commands
 Totalizer Commands
Scpi Command Summary Digital Input Commands
See page 255 for more information
See page 256 for more information
 DAC Output Commands
Scpi Command Summary Digital Output Commands
Switch Control Commands
See page 258 for more information
 State Storage Commands
Scpi Command Summary Scan Triggering Commands
See page 228 for more information
See page 261 for more information
 See page 264 for more information
Scpi Command Summary System-Related Commands
 Status System Commands
Scpi Command Summary Interface Configuration Commands
See page 269 for more information
See page 286 for more information
 Service-Related Commands
Scpi Command Summary Calibration Commands
See page 292 for more information
See page 294 for more information
 Scpi Command Summary Ieee 488.2 Common Commands
 Simplified Programming Overview
Simplified Programming Overview
 Using the CONFigure Command
Using the MEASure? Command
 Using the range and resolution Parameters
 Using the INITiate and FETCh? Commands
Using the READ? Command
 205
 Trigsour EXT Init FETC?
 MEASure? and CONFigure Commands
MEASure? and CONFigure Commands
MEASure? Command Syntax
MEASureTEMPerature?5 TCouple,BEJKNRSTDEF
 MEASureTEMPerature? THERmistor,2252500010000DEF
MEASureTEMPerature? RTDFRTD,8591DEF
MEASureVOLTageDC? MEASureVOLTageAC? RangeAUTOMINMAXDEF
 MEASureCURRentDC? MEASureCURRentAC? RangeAUTOMINMAXDEF
MEASureRESistance? MEASureFRESistance? RangeAUTOMINMAXDEF
On the 34901A multiplexer module
 MEASureDIGitalBYTE? @scanlist
MEASureTOTalize? READRRESet ,@scanlist
 CONFigureTEMPerature TCouple,BEJKNRSTDEF
MEASure? and CONFigure Commands CONFigure Command Syntax
CONFigureTEMPerature RTDFRTD,8591DEF
CONFigureTEMPerature THERmistor,2252500010000DEF
 CONFigureRESistance CONFigureFRESistance RangeAUTOMINMAXDEF
CONFigureVOLTageDC CONFigureVOLTageAC RangeAUTOMINMAXDEF
CONFigureCURRentDC CONFigureCURRentAC RangeAUTOMINMAXDEF
 CONFigureDIGitalBYTE @scanlist
CONFigureFREQuency CONFigurePERiod RangeAUTOMINMAXDEF
CONFigureTOTalize READRRESet ,@scanlist
CONFigure? @chlist
 Setting the Function, Range, and Resolution
Setting the Function, Range, and Resolution
See also General Measurement Configuration in starting on
SENSeFUNCtion function,@chlist
 Setting the Function, Range, and Resolution
 Setting the Function, Range, and Resolution
 Setting the Function, Range, and Resolution
 Setting the Function, Range, and Resolution
 General Temperature Commands
Temperature Configuration Commands
SENSeTEMPeratureTRANsducer
SENSeTEMPerature Nplc 0.020.2121020100200MINMAX,@chlist
 Temperature Configuration Commands Thermocouple Commands
 SENSeTEMPeratureRJUNction? @ch list
 Thermistor Commands
Temperature Configuration Commands RTD Commands
 See also Voltage Measurement Configuration in starting on
Voltage Configuration Commands
INPut
SENSe Zeroauto OFFONCEON,@chlist ZEROAUTO? @chlist
 Current Configuration Commands
Resistance Configuration Commands
See also Current Measurement Configuration in starting on
 Frequency Configuration Commands
Frequency Configuration Commands
See also Frequency Measurement Configuration in starting on
 Scanning Overview
Scanning Overview
See also Scanning in starting on
 Scan Interval
 TRIGger SOURce BUSIMMediateEXTernalALARm1234TIMer SOURce?
Scanning Overview Scanning Commands
ROUTe Scan @scanlist SCAN?
ROUTeSCANSIZE?
 ROUTe CHANnelDELay seconds,@ch list CHANnelDELay? @chlist
TRIGger TIMer secondsMINMAX TIMer?
TRIGger COUNt countMINMAXINFinity COUNt?
 ABORt
ROUTe
INITiate
 FORMat READingALARm Offon READingALARm?
Scanning Overview Reading Format Commands
FORMat READingCHANnel Offon READingCHANnel?
 FORMat READingUNIT Offon READingUNIT?
FORMat READingTIME Offon READingTIME?
FORMat READingTIMETYPE ABSoluteRELative READingTIMETYPE?
 CALCulateAVERageMINimum? @chlist
Scanning Overview Scan Statistics Commands
CALCulateAVERageMINimumTIME? @chlist
CALCulateAVERageMAXimum? @chlist
 CALCulateAVERagePTPeak? @chlist
CALCulateAVERageAVERage? @chlist
CALCulateAVERageCOUNt? @chlist
CALCulateAVERageCLEar @chlist
 DATAPOINts?
Scanning Overview Scan Memory Commands
DATAREMove? numrdgs
 SYSTemTIMESCAN?
See Reading Format Commands on
FETCh?
 Single-Channel Monitoring Overview
Single-Channel Monitoring Overview
 ROUTe MONitorSTATe Offon MONitorSTATe?
ROUTe MONitor @channel MONitor?
ROUTeMONitorDATA?
 Scanning With an External Instrument
 TRIGger SOURce BUSIMMediateEXTernalTIMer SOURce?
 TRIGger COUNt valueMINMAXINFinity COUNt?
 Scanning With an External Instrument
 INSTrument
INSTrumentDMMINSTalled?
 Mx+B Scaling Overview
Mx+B Scaling Overview
See also Mx+B Scaling in starting on
 CALCulate
Mx+B Scaling Overview Mx+B Scaling Commands
 CALCulateSCALeOFFSetNULL @chlist
 Alarm System Overview
Alarm System Overview
See also Alarm Limits in starting on
 Alarm System Overview
 Calclimitupper MAX,@101LOWER 9,@101LOWERSTATE on
 OUTPut ALARm1234SOURce @chlist ALARm1234SOURce?
Alarm System Overview Alarm Limit Commands
CALCulate LIMitUPPer value,@ch list LIMitUPPer? @chlist
 CALCulate LIMitLOWer value,@ch list LIMitLOWer? @chlist
SYSTemALARm?
 OUTPut ALARmMODE LATChTRACk ALARmMODE?
Alarm System Overview Alarm Output Commands
OUTPut ALARmSLOPe NEGativePOSitive ALARmSLOPe?
 COMPareDATA? @chlist
Digital I/O Alarm Commands
 COMPareMASK mask,@chlist COMPareMASK? @chlist
 See also Digital Input Operations in starting on
Digital Input Commands
SENSeDIGitalDATABYTEWORD? @chlist
 SENSe TOTalizeTYPE READRRESet,@chlist TOTalizeTYPE? @chlist
Totalizer Commands
See also Totalizer Operations in starting on
 SENSeTOTalizeCLEarIMMediate @chlist
Commands see Reading Format Commands on
SENSeTOTalizeDATA? @chlist
 DAC Output Commands
Digital Output Commands
SOURceDIGitalSTATe? @chlist
SOURce
 Switch Control Commands
 SYSTemCPON 100200300ALL
ROUTeDONE?
This is equivalent to pressing from the front panel
 SAV
State Storage Commands
RCL
 MEMorySTATeDELete
MEMorySTATe Name 12345 ,name NAME?
 MEMorySTATeVALid?
RECallAUTO?
MEMoryNSTates?
 See also System-Related Operations in starting on
System-Related Commands
SYSTemDATE yyyy,mm,dd
SYSTemDATE?
 SYSTemCTYPe?
IDN?
 DISPlay
DISPlay Offon DISPlay?
DISPlayTEXTCLEar
 INSTrument DMM Offon
SYSTemPRESet
 See for a complete listing of the 34970A error messages
SYSTemERRor?
SYSTemVERSion?
 Interface Configuration Commands
 RS-232 Configuration Overview
RS-232 Interface Configuration
RS-232 Interface Configuration
 RS-232 Flow Control Modes
 Connection to a Computer or Terminal
RS-232 Data Frame Format
 RS-232 Troubleshooting
 Modem Communications
Modem Communications
For more information, see Flow Control Selection on
S0=1
 What is an Event Register?
What is a Condition Register?
What is an Enable Register?
Scpi Status System
 Agilent 34970A Status System
 Bit Definitions Status Byte Register
Status Byte Register
Decimal Bit Number
Definition
 Using *STB? to Read the Status Byte
Using Service Request SRQ and Serial Poll
 To Interrupt Your Bus Controller Using SRQ
Using the Message Available Bit MAV
To Determine When a Command Sequence is Completed
 Bit Definitions Questionable Data Register
Questionable Data Register
 Scpi Status System
 Bit Definitions Standard Event Register
Standard Event Register
 Scpi Status System
 Bit Definitions Alarm Register
Alarm Register
 Bit Definitions Standard Operation Register
Standard Operation Register
 Status Byte Register Commands
Status System Commands
See the table on page 277 for the register bit definitions
 See the table on page 280 for the register bit definitions
Questionable Data Register Commands
 See the table on page 282 for the register bit definitions
Status System Commands Standard Event Register Commands
 STATusALARmCONDition?
Status System Commands Alarm Register Commands
STATusALARmEVENt?
STATusALARmENABle enablevalue STATusALARmENABle?
 STATusOPERationENABle enablevalue STATusOPERationENABle?
Status System Commands Standard Operation Register Commands
See the table on page 285 for the register bit definitions
STATusOPERationCONDition?
 STATusPRESet
Miscellaneous Status Register Commands
DATAPOINtsEVENtTHReshold numrdgs DATAPOINtsEVENtTHReshold?
PSC
 CALibration?
Calibration Commands
CALibrationCOUNt?
CALibrationSECureCODE newcode
 CALibrationSTRing quotedstring
CALibrationSECureSTATe OFFON,code CALibrationSECureSTATe?
CALibrationSTRing?
CALibrationVALue value CALibrationVALue?
 DIAGnosticDMMCYCLes?
Service-Related Commands
DIAGnosticDMMCYCLesCLEar
DIAGnosticRELayCYCLes? @chlist
 WAI
 An Introduction to the Scpi Language
An Introduction to the Scpi Language
 Command Format Used in This Manual
 Using the MIN and MAX Parameters
Command Separators
 Scpi Command Terminators
Querying Parameter Settings
IEEE-488.2 Common Commands
 Scpi Parameter Types
 301
 Using Device Clear
Using Device Clear
 Error Messages
 Error Messages
 Execution Errors
 121
Execution Errors 114
123
124
 178
Execution Errors 168
211
213
 310
Execution Errors 230
350
410
 Instrument Errors
 225
Instrument Errors 221
226
 271
Instrument Errors 261
272
281
 305
Instrument Errors 303
306
 502
Instrument Errors 501
511
512
 601
Self-Test Errors
602
603
 Calibration Errors
 720
Calibration Errors 710
721
722
 901
Plug-In Module Errors
902
903
 318
 Application Programs
 Application Programs
 Example Programs for Excel
Example Programs for Excel
 VISAaddr =
Excel 7.0 Example takeReadings Macro
 323
 324
 Dim columnIndex As Integer
Excel 7.0 Example ScanChannels Macro
 326
 327
 Example Programs for C and C++
Example Programs for C and C++
 ++ Example dacout.c
 ++ Example statreg.c
 331
 332
 Tutorial
 Tutorial
Matrix Switching, starting on
 System Cabling and Connections
Cable Specifications
System Cabling and Connections
 Cable Type Nominal Impedance Capacitance Attenuation
Ft 2 conductors
 Grounding Techniques
 Shielding Techniques
Separation of High-Level and Low-Level Signals
 Sources of System Cabling Errors
 Copper-to Approx. ∝V / C
 Discussion of integration time
Where
 Voltage Measured = √ V + Noise
 Measurement Fundamentals
Measurement Fundamentals
 NMR
Integration Time PLCs
 RTD
Temperature Measurements
 Measurement Fundamentals
 Internal DMM
 Internal DMM Ice Bath
 349
 Measurement Fundamentals
 Iron Constantan
Temperature Probe Type Pos + Lead Neg Lead
Nickel-Chromium Nickel-Aluminum
Copper Constantan
 Sources of Error in Thermocouple Measurements
 Without Shield
 DC Voltage Measurements
 Or greater see page 103 for a discussion of integration time
Sources of Error in DC Voltage Measurements
 Connection a Connection B
 Rs + Ri
 358
 AC Voltage Measurements
 360
 361
 Sources of Error in AC Voltage Measurements
 363
 For low frequencies
 + Noise
 Measurement Fundamentals
 Current measurements are allowed only on the 34901A module
Current Measurements
 Sources of Error in AC Current Measurements
Sources of Error in DC Current Measurements
 Resistance Measurements
 370
 Measurement Fundamentals
 Insulating Material Resistance Range Moisture Absorbing
Sources of Error in Resistance Measurements
 Strain Gage Measurements
 HI Source HI Sense LO Sense LO Source
 DMM Sensitivity
Strain
 Frequency and Period Measurements
 Sources of Error in Frequency and Period Measurements
 Low-Level Signal Multiplexing and Switching
Low-Level Signal Multiplexing and Switching
 Two-Wire Multiplexers
One-Wire Single-Ended Multiplexers
 Four-Wire Multiplexers
 Signal Routing and Multiplexing
 Sources of Error in Multiplexing and Switching
 Module Bank
 Actuators and General-Purpose Switching
Actuators and General-Purpose Switching
 RC Protection Networks
Snubber Circuits
 Using Varistors
 Using Attenuators
 Matrix Switching
Matrix Switching
 Matrix Module
Combining Matrices
 RF Signal Multiplexing
RF Signal Multiplexing
 Insertion Loss 75Ω
Sources of Error in RF Switching
 Digital Input
Multifunction Module
Multifunction Module
 Digital Output
 Driving External Switches
Using an External Pull-Up
 Totalizer
 Totalizer Errors
 Voltage DAC Output
 DAC Errors
 Relay Life and Preventative Maintenance
Relay Life and Preventative Maintenance
 Relay Load
Relay Life
 Replacement Strategy
Switching Frequency
 402
 Specifications
 DC, Resistance, and Temperature Accuracy Specifications
DC, Resistance, and Temperature Accuracy Specifications
 DC Measurement and Operating Characteristics
DC Measurement and Operating Characteristics
 AC Accuracy Specifications
AC Accuracy Specifications
 AC Measurement and Operating Characteristics
AC Measurement and Operating Characteristics
 Measurement Rates and System Characteristics
Measurement Rates and System Characteristics
 Module Specifications
Module Specifications
 34905A, 34906A
 Typical AC Performance Graphs
Typical AC Performance Graphs
Insertion Loss 75 Ω
Crosstalk 75 Ω
 34907A
Software Specifications
 Product and Module Dimensions
Product and Module Dimensions
 To Calculate Total Measurement Error
To Calculate Total Measurement Error
 415
 Interpreting Internal DMM Specifications
Interpreting Internal DMM Specifications
Number of Digits and Overrange
Sensitivity
 Accuracy
Resolution
Criteria
 Hour Accuracy
Temperature Coefficients
Day and 1-Year Accuracy
 Configuring for Highest Accuracy Measurements
Configuring for Highest Accuracy Measurements
 420
 Index
Totalize Threshold jumper, 135, 175 totalizer reset mode
 Index
 423
 424
 425
 426
 427
 428
 429
 430
 431
 432
 433
 434
 U T I O N
 Declaration of Conformity