Index

SOUR:DIG:DATA:BYTE command, 258

STATus:QUES:ENABle command, 287

SYSTem:REMote command, 269

 

SOUR:DIG:DATA:WORD command, 258

STATus:QUES:EVENt? command, 287

SYSTem:RWLock command, 269

 

SOUR:DIG:STATe? command, 258

Step key, 24, 78

 

 

 

SYSTem:TIME command, 264

 

SOUR:VOLTage command, 258

Sto/Rcl key, 36, 48

 

 

SYSTem:TIME:SCAN? command, 236

SCPI language, short form,

297

stop bits (RS-232),

270

 

SYSTem:VERSion?,

268, 295

 

SPDT (Form C) switching,

59, 384

stopping scan,

81

 

 

 

SYSTem:VERSion? command, 268

specifications,

203-220

 

 

stored states

 

 

 

 

 

 

 

 

ac accuracy,

406

 

 

412

definition, 48

 

 

 

T

 

 

 

BenchLink Data Logger,

front-panel operation, 141

TEMP:TRAN:FRTD:RES command, 222

dc accuracy,

404

 

 

 

naming states,

48, 140

 

 

 

 

 

TEMP:TRAN:FRTD:TYPE command, 222

plug-in modules, 409

 

 

power-down recall, 140

 

 

 

 

TEMP:TRAN:RTD:RES command, 222

speed, scanning, 405, 407

 

remote operation,

141

 

 

 

TEMP:TRAN:RTD:TYPE command, 222

standard event register

 

 

strain gage

 

 

 

 

 

 

 

 

 

 

TEMP:TRAN:TC:CHECk command, 221

bit definitions, 282

 

 

common uses, 374

 

 

 

 

TEMP:TRAN:TC:RJUN command, 221

clearing bits, 283

 

 

 

gage factor,

374

 

 

 

 

 

 

 

TEMP:TRAN:THER:TYPE command, 222

standard operation register

 

measurements,

120, 373

 

TEMP:TRAN:TC:RJUN:TYPE command, 220

bit definitions, 285

 

 

Mx+B equations,

120

 

 

 

 

TEMP:TRAN:TC:TYPE command, 220

clearing bits, 285

 

 

 

poisson strain, 373

 

 

 

 

 

TEMP:TRAN:TYPE command, 219

 

Standby (Power) switch,

17

rosette, 374

 

 

 

 

 

 

 

 

 

temperature coefficient, 366

 

state storage

 

 

 

 

shearing strain,

373

 

 

 

 

 

 

 

temperature conversion accuracy,

345

definition, 48

 

 

 

Wheatstone bridge, 375

 

 

 

temperature measurements

 

front-panel operation,

141

strain relief, 20, 335

 

 

 

 

 

RTDs, 110

 

 

 

naming states, 48, 140

 

stress (strain gage),

373

 

 

 

 

 

 

thermistors, 112

 

 

power-down recall,

140

 

string parameters,

301

 

 

 

 

 

thermocouples, 107

 

remote operation,

141

 

 

strip length, wiring,

20

 

 

 

 

 

temperature units,

106

 

statistics, while scanning, 75

sweep (scan), defined, 78, 80

 

temperature, product operating,

408

status byte

 

 

 

 

switch contact resistance,

399

 

 

 

 

terminal connections

 

bit definitions, 277

 

 

switch life, 399

 

 

 

 

 

 

 

 

 

ac current,

21

 

 

clearing bits, 277

 

 

 

switch types

 

 

 

 

 

 

 

 

 

 

 

 

 

ac voltage,

21

 

 

status register

 

 

 

 

form C (SPDT),

59

 

 

 

 

 

 

 

 

ac current,

21

 

 

alarm register, 284

 

 

matrix, 59

 

 

 

 

 

 

 

 

 

 

 

 

dc voltage,

21

 

 

condition register,

275

 

multiplexer,

58, 378

 

 

 

 

 

frequency,

21

 

 

enable register, 275

 

 

switching, errors,

381

 

 

 

 

 

 

period, 21

 

 

 

example program,

330

 

syntax, SCPI conventions,

73, 181

 

 

 

 

resistance,

21

 

 

event register, 275

 

 

system cabling, 55, 335

 

 

 

 

 

 

RTDs, 21

 

 

 

questionable data register, 280

system clock

 

 

 

 

 

 

 

 

 

 

 

thermistors, 21

 

 

register diagram, 276

 

 

factory setting,

145

 

 

 

 

 

 

thermocouples, 21

 

standard event register,

282

setting the,

22, 145

 

 

 

wire strain relief,

20

 

standard operation register, 285

system speeds,

408

 

 

 

 

 

wire strip length,

20

 

status byte,

277

 

 

 

SYSTem:ALARm? command, 251, 268

 

 

 

 

thermal EMF errors, 340

 

STATus:ALARm:COND? command, 289

SYSTem:CPON command, 260, 295

 

thermocouple, metals used, 351

 

STATus:ALARm:ENABle command, 289

SYSTem:CTYPe? command, 265

 

thermistors

 

 

 

STATus:ALARm:EVENt? command, 289

SYSTem:DATE command, 264

 

 

 

connections, 21

 

 

STATus:OPER:COND? command, 290

SYSTem:ERRor? command, 268, 304

 

 

conversion accuracy, 345

 

STATus:OPER:ENABle command, 290

SYSTem:INTerface command, 269

 

measurement tutorial, 112, 346

STATus:OPER:EVENt? command, 290

SYSTem:LOCal command, 269

measurement units, 106

 

STATus:PRESet? command, 291

SYSTem:PRESet command, 161, 267

 

types supported,

21, 106

 

STATus:QUES:COND? command, 287

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Index

431

Page 433
Image 433
Agilent Technologies 34970A manual 431

34970A specifications

Agilent Technologies 34970A is a versatile data acquisition and measurement system that has gained popularity in various industries, including research and development, manufacturing, and education. The primary purpose of the 34970A is to offer an efficient solution for data collection, monitoring, and analysis, which can significantly enhance productivity and accuracy in testing applications.

One of the main features of the 34970A is its modular design, allowing users to customize the system according to their specific measurement needs. The mainframe can accommodate up to three plug-in measurement modules, which can include various types of measurements such as analog, digital, temperature, and frequency. This modularity provides flexibility for users to tailor the system to their requirements, making it highly adaptable to different applications.

Another notable characteristic of the Agilent 34970A is its impressive channel configuration. The system can support up to 120 measurement channels when fully configured, enabling extensive data acquisition without the need for multiple devices. This capability is essential for applications requiring simultaneous monitoring of multiple parameters or locations.

The 34970A utilizes advanced signal processing technologies to ensure high-accuracy measurements. The internal 6.5-digit resolution multimeter provides precise readings, while the device also supports various input types, such as thermocouples and RTDs for temperature measurements. The ability to perform mathematical functions, such as summation and averaging, on the acquired data further enhances its usability.

For data storage and management, the Agilent 34970A features built-in memory for storing up to 20,000 readings. Users can also easily transfer data to a PC through the RS-232 interface or GPIB (IEEE 488) for further analysis and reporting. Additionally, it offers the capability to program automatic data logging and scheduling of measurements, which streamlines the testing process and reduces manual intervention.

In terms of user interface, the 34970A is equipped with a large graphical display that provides clear visualization of measurement data and easy navigation through settings and options. The menu-driven interface makes it accessible for users of all skill levels, simplifying the setup and operation of the device.

Overall, the Agilent Technologies 34970A stands out for its modularity, high channel capacity, advanced measurement technologies, and user-friendly interface. As a reliable and efficient data acquisition system, it is well-suited for a wide range of applications, making it an essential tool for engineers and technicians looking to enhance measurement precision and efficiency.