System Information

C

Item

Description

Specification

 

 

 

 

Power

DC power jack 100 mils, positive center

 

 

 

Miscellaneous

Operating temperature range

0°C to 55°C

 

 

 

 

Maximum relative humidity

80% for temperatures up to 31°C, decreasing

 

 

linearly to 50% relative humidity at 40°C

 

 

 

 

Storage temperature range

– 40°C to +70°C

 

Dimensions

6 in x 3-5/8 in x 8 in

 

 

15.24 cm x 9.21 cm x 20.32 cm

 

 

 

 

Weight

4.6 lbs (2.1 kg)

 

 

 

 

Power

9 to 34 V DC, 9W

 

Power (internal GPS option 200)

9 to 34 V DC, 10W

 

AC Power

100 - 240 Volts AC

 

 

50 - 60 Hz

 

 

 

Internal GPS(Option

GPS Receiver

8 Channel internal GPS receiver

200)

 

 

 

Connector type

SMA

Differential compatible without dead reckoning

Note: Internal GPS is standard on all “C” receivers. It can be disabled if you wish to use an external GPS system.

* It is recommended the input signal level not exceed – 40 dBm.

Adjacent channel desensitization applies to wideband mode (1.25 MHz IF filter) and is defined as: 1 dB compression of tuned signal with interfering signal 1.25 MHz from tuned signal.

Receivers (with the exception of “C” receivers) fitted with an internal GPS do not support connection to external GPS receiv- ers.

Agilent E6474A User’s Guide

147

Page 147
Image 147
Agilent Technologies Agilent E6474A manual Description Specification, Miscellaneous, Internal GPS‡ Option