Set Up Your System 3

Connections for receiver 2

1Connect RX LOOP IN on receiver 1 to RX LOOP OUT on receiver 2 using cable E6450-60002.

2Connect RX LOOP OUT on receiver 1 to RX LOOP IN on receiver 2 using cable E6450-90001.

3Connect power on receiver 2 to Aux Out socket on the E6473B hub using cable E6473-60091.

Refer to Figure 15 on page 43.

E6473-60106

Receiver 1

to RF antenna

E6450-60002

E6450-60001

to RF antenna

to optional GPS

to vehicle power

E6473B Hub

Receiver 2

E6473-60091

Figure 15 Data and power connection for two receivers

Agilent E6474A User’s Guide

43

Page 43
Image 43
Agilent Technologies Agilent E6474A manual Receiver