Agilent Technologies manual Testing the signal, Agilent E6474A User’s Guide

Models: Agilent E6474A

1 184
Download 184 pages 57.82 Kb
Page 109
Image 109
Testing the signal

Get Assistance, if You Need It

6

Figure 51 Spectrum Display with Marker Set to a Center Frequency of 1960MHz(CDMA 1900 band system)

Testing the signal

1In the Markers group, click Add and To Max. The level and frequency are displayed at the top-left corner of the Spectrum Analyzer display.

2In the Band group, select Downlink.

3In the Freq/Channel group, change the Center frequency according to Table 4 on page 110.

4On the signal generator, set the frequency according to Table 4 on page 110.

You should see a signal trace showing a single spectral peak in the middle of the display. Figure 52 on page 110 shows an example trace.

Agilent E6474A User’s Guide

109

Page 109
Image 109
Agilent Technologies manual Testing the signal, Agilent E6474A User’s Guide