Agilent Technologies Agilent E6474A E6455C 2.1 GHz W-CDMA/UMTS/cdma2000 receiver specifications

Models: Agilent E6474A

1 184
Download 184 pages 57.82 Kb
Page 158
Image 158
E6455C 2.1 GHz W-CDMA/UMTS/cdma2000 receiver specifications

CSystem Information

E6455C 2.1 GHz W-CDMA/UMTS/cdma2000 receiver specifications

Item

Description

Specification

 

 

 

Frequency

Frequency range

1920 to 1980 MHz [1895-1990] 2110 to 2170 MHz

 

 

[2100-2180]

 

 

 

 

Frequency accuracy With GPS time

±1 ppm

 

synchronization

±0.05 ppm, characteristic

 

 

 

 

IF bandwidth

1.25 MHz, characteristic

 

 

5 MHz, characteristic

 

 

 

 

Aging of TCXO

±1 ppm/year

 

 

 

Amplitude

Accuracy 1.25 MHz IF

± 0.5 dB typical from – 25 dBm to – 110 dBm (20° to

 

 

30°C)

 

 

 

 

Accuracy, 5 MHz IF

±0.5 dB typical from – 25 dBm to – 100 dBm (20° to 30°C)

 

 

 

 

Noise figure

8.0 dB typical

 

 

 

 

Maximum safe input level

+10 dBm, 20V DC, characteristic

 

 

 

 

1 dB compression point *

– 15 dBm, characteristic

 

Adjacent channel desensitization

– 20 dBm typical

 

Adjacent channel rejection

25 dB typical

 

Internally generated spurious, input

– 120 dBm for 1.25 MHz -115 dBm for 5 MHz

 

referred

 

 

 

 

Input/Output

RF input

50Type-N

 

 

 

Connectors

Computer

RS-232 (DB9) Male

 

 

 

 

GPS

RS-232 (DB9) Male

 

 

 

 

Power

DC power jack 100 mils, positive center

 

 

 

Miscellaneous

Operating temperature range

0°C to 55°C

 

 

 

 

Maximum relative humidity

80% for temperatures up to 31°C, decreasing linearly to

 

 

50% relative humidity at 40°C

 

 

 

 

Storage temperature range

– 40°C to +70°C

 

 

 

 

Dimensions

6 in x 3-5/8 in x 8 in

 

 

15.24 cm x 9.21 cm x 20.32 cm