Programming and Syntax Diagram Conventions

Introduction to Programming

The Agilent 8164A/B slot for a back-loadable tunable laser module is

N O T E

numbered zero.

 

 

 

 

Channel numbers apply to modules that have two inputs/outputs, for

 

example, the Agilent 81635A Dual Power Sensor.

 

Modules with two channels, for example, the Agilent 81635A Dual Power

 

Sensor, use the channel number to distinguish between these channels.

 

The channel number of single channel modules is always one.

N O T E

 

 

 

 

 

 

For example, if you want to query slot 1, channel 2 with the command,

 

“:SENSe[n]:[CHANnel[m]]:POWer:WAVelength?” on page 109, you should

 

send the command:

 

:sens1:chan2:pow:wav?

 

If you do not specify a slot or channel number, the lowest possible number

N O T E

is used as the default value. This means:

 

 

Slot 1 for the Agilent 8163A/B and Agilent 8166A/B mainframes.

 

• Slot 0 for the Agilent 8164A/B mainframe.

 

• Channel 1 for all channels.

 

 

 

Laser Selection Numbers

The laser selection number, [l], identifies the upper or lower wavelength laser source for dual wavelength Laser Source modules and Return Loss modules with two internal laser sources. The lower wavelength source is denoted by 1. The upper wavelength source is denoted by 2.

Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition

27

Page 27
Image 27
Agilent Technologies 8164A, B, 8166A, 8163A manual Laser Selection Numbers

8163A, 8164A, 8166A, B specifications

Agilent Technologies B,86100A is a high-performance oscilloscope and signal integrity analyzer designed primarily for advanced digital communications applications. As a versatile tool, it supports a wide range of testing needs, making it indispensable for engineers and researchers involved in the development and testing of high-speed digital signals.

One of the standout features of the B,86100A is its capability to analyze signals with various bandwidths, accommodating both current and emerging communication standards. The device features a sampling rate of up to 80 GS/s and bandwidth capabilities of 33 GHz to ensure high accuracy in capturing fast signal transitions, which is critical for ensuring the integrity of complex digital signals.

The B,86100A employs Agilent's proprietary digital signal processing (DSP) technology, which significantly enhances measurement precision and reduces noise, enabling users to obtain clearer insights into signal behavior. Its advanced triggering capabilities allow for precise signal capture, making it particularly useful in troubleshooting and validating high-speed designs, as well as in evaluating the performance of optical and electrical devices.

In addition to its high-speed capabilities, the B,86100A offers a robust set of measurement tools including jitter analysis, eye diagram analysis, and equalization assessment. These features allow engineers to effectively analyze signal quality and address potential issues related to signaling distortions and inter-symbol interference.

The graphical user interface of the B,86100A is intuitive, enabling users to efficiently navigate through measurement options and visualize data results. Customizable measurement setups streamline workflow, ensuring that users can quickly adapt their tests to evolving project requirements.

Another key characteristic of the B,86100A is its modularity. The system supports a variety of plug-in modules, which can be tailored to specific application needs, such as different types of optical and electrical signals. This flexibility not only extends the operational capability of the instrument but also makes it a future-proof investment as technology continues to evolve.

In summary, Agilent Technologies B,86100A combines high-speed acquisition with advanced processing capabilities, making it an essential instrument for anyone involved in high-speed digital design and testing. With its ability to deliver precise measurements and extensive analysis features, it empowers engineers to achieve optimal performance and reliability in their systems.