Allen-Bradley 1336-Series AC Drives

Displaying Metering Information

1.Install the HIM on the A-B drive.

2.Turn on machine power.

3.After three to five seconds of initialization, display will show the status display. If drive is in a faulted condition, fault will appear in display; otherwise, drive will read current status. Refer to examples below.

Faulted Drive

Normal Condition

6.Press the Enter key to choose Group Level. Display will read:

Choose Group

Metering

For earlier HIM versions, press the Enter key to choose Main File. Display will read:

Metering

Main File

Fault Description Fault Number

Examples of Faults

Serial Fault

F 10

Max Retries Fault F 33

Status of Drive Frequency Commanded

Example of Normal

Condition

Stopped

+0.00 Hz

7.Use the Up and Down arrow keys to select “Metering” if not displayed immediately.

8.Press the Enter key to choose Parameter Level. Display now shows parameters under the “Metering” Group.

Output Current

0.00 Amps

4. Press any key to enter Mode Level,

ESC SEL

. Display will read:

Choose Mode

Display

5.Use the Up and Down arrow keys to select “Display” if not displayed immediately.

9.

Use the Up and Down arrow keys

to

 

select desired parameter display.

 

10.

From this point, press the Escape key

ESC to

 

move display up one Level (i.e., press the Escape

 

key three times to return to Operator Level).

102