Allen-Bradley 1336-Series AC Drives

Table 56 (continued)

Allen-Bradley Drive Fault Codes (continued)

 

Fault

Description

Corrective Action

 

Remarks

 

 

 

 

 

 

 

39

Phase V Fault

Phase to ground fault detected

Check wiring between the drive and motor. Check for

 

 

between controller and motor in

grounded phase.

 

 

Phase V.

 

 

 

 

 

40

Phase W Fault

Phase to ground fault detected

Check wiring between the drive and motor. Check for

 

 

between controller and motor in

grounded phase.

 

 

Phase W.

 

 

 

 

 

41

UV Short Fault

Excessive current has been

Check motor and external wiring to the controller output

 

 

detected between two controller

terminals for shorted condition.

 

 

output terminals.

 

 

 

 

 

42

UW Short Fault

Excessive current has been

Check motor and external wiring to the controller output

 

 

detected between two controller

terminals for shorted condition.

 

 

output terminals.

 

 

 

 

 

43

VW Short Fault

Excessive current has been

Check motor and external wiring to the controller output

 

 

detected between two controller

terminals for shorted condition.

 

 

output terminals.

 

 

 

 

 

57

Ground Warning

A current path to ground in excess

Check motor and external wiring to drive output terminals

 

 

of 2A has been detected at one or

for a grounded condition.

 

 

more of the drive output terminals.

 

 

 

 

 

48

Reset to Default Values

Parameters were reset to the

Verify and re-load the desired parameters.

 

 

factory default values.

 

 

 

 

 

Table 56

108

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232120