Allen-Bradley 1336-Series AC Drives

Allen-Bradley Drive Fault Codes

Allen-Bradley Drive Fault Codes

 

Fault

Description

Corrective Action/

 

Remarks

 

 

 

 

 

 

 

02

Motor Temp

The motor thermal switch path is

Motor temperature high. Check for: ambient air, cooling

 

Fault

open.

fan blockage or operation, break in switch wire path (not

 

 

 

on all machines).

 

 

 

 

03

Power Loss Fault

DC Bus voltage remains below

Monitor incoming AC line for low voltage or line power

 

 

85% nominal for longer than .5

interruption.

 

 

seconds.

 

 

 

 

 

04

Under Voltage Fault

DC Bus voltage fell below

Monitor AC incoming AC line for low voltage or line

 

 

minimum.

power interruption.

 

 

 

 

05

Over Voltage Fault

DC Bus maximum voltage

Monitor the AC line for high line voltage or transient

 

 

exceeded.

conditions. High voltage can result from motor

 

 

 

regeneration. Buck transformer may be required.

 

 

 

 

06

Motor Stall

Motor has stalled. Motor load is

Check motor wiring and connection terminals. Check wash

 

 

excessive.

basket freedom of movement and excess belt tension.

 

 

 

 

07

Motor Overload Fault

Internal electronic overload trip.

Check motor wiring and connection terminals. Check wash

 

 

Excessive motor load exists.

basket freedom of movement and excess belt tension.

 

 

 

 

08

Over Temperature Fault

Excessive heat detected by

Clear blocked or dirty heatsink fins. Check ambient

 

 

heatsink transducer.

temperature. Check for blocked or nonoperating fan.

 

 

 

 

10

Serial Fault

Drive lost communication with

HIM removed while power applied, cycle power to clear.

 

 

controlling device.

 

 

 

 

 

12

Overcurrent Fault

Overcurrent detected in

Check short circuit at the controller output or excessive

 

 

instantaneous hardware trip circuit.

load conditions at motor.

 

 

 

 

22

Controller Reset Fault

Stop input not present.

Check stop input into control terminal board. Close door

 

 

 

and ensure any jumpers are placed correctly.

 

 

 

 

32

EEPROM Fault

EEProm has invalid data.

Consult the factory for further instructions.

 

 

 

 

33

Max Retries Fault

Controller failed to reset fault

Fault exists that must be corrected before further operation.

 

 

within the number of retries.

Check “Fault Buffer 1” on 1305 and 1336 for specific fault

 

 

 

that triggered max retries fault.

 

 

 

 

38

Phase U Fault

Phase-to-ground fault detected

Check wiring between the drive and motor. Check for

 

 

between controller and motor in

grounded phase.

 

 

Phase U.

 

 

 

 

 

Table 56 (continued)

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

107