Displaying Fault Buffers
1.Install the HIM on the
2.Turn on machine power.
3.After three to five seconds of initialization, display will show the status display. If drive is in a faulted condition, fault will appear in display; otherwise, drive will read current status. Refer to examples below.
Faulted Drive |
| Normal Condition |
|
|
|
Fault Description |
| Status of Drive |
Fault Number |
| Frequency Commanded |
|
|
|
6.Press the Enter key to choose Group Level. Display will read:
Choose Group
Faults .
For earlier HIM versions, press the Enter key to choose Main File. Display will read:
Faults
Main File
7. Use the Up and Down arrow keys | to |
select “Faults.” |
|
Examples of Faults
Serial Fault
F 10
Max Retries Fault F 33
Example of Normal
Condition
Stopped
+0.00 Hz
8. Press the Enter key | to choose Parameter |
Level. Display now shows parameters under the | |
“Faults” Group. |
|
Fault Buffer 0
48
4. Press any key to enter Mode Level,
ESC SEL
. Display will read:
Choose Mode
Display
5.Use the Up and Down arrow keys to select “Display” if not displayed immediately.
9.Use the Up and Down arrow keys to select desired fault buffer display.
10.From this point, press the Escape key ESC to move display up one Level (i.e., press the Escape key three times to return to Operator Level).