Controller Object Commands
/cx set autorebuild=onoff
This command is only for 9550SX , 9590SE, and 9650SE controllers.
This command turns the
If the policy is on the firmware will select drives to use for rebuilding a degraded unit using the following priority order.
1.Smallest usable spare.
2.Smallest usable unconfigured (available) drive.
3.Smallest usable failed drive.
Note: Failed drives can be drives that have mechanically failed, or they can be drives that have been disconnected from the controller long enough for the controller to classify them as failed.
Enabling
If the policy is off, spares are the only candidates for rebuild operations.
Example:
//localhost> /c0 set autorebuild=enable
Setting
/cx set autodetect=onoff disk=<p:-p>all
This command is only for 9000 series controllers.
This command is associated with the staggered
Note: The autodetect setting cannot be shown in CLI or displayed in 3DM or 3BM.
This feature may be added in a future release.
www.3ware.com | 57 |