Chapter 1. Introduction to the 3ware Command Line Interface

Figure 3. RAID 5 Configuration Example

RAID 6

RAID 6 requires a 3ware 9650SE RAID controller.

RAID 6 provides greater redundancy and fault tolerance than RAID 5. It is similar to RAID 5, but has two blocks of parity information (P+Q) distributed across all the drives of a unit, instead of the single block of RAID 5.

Due to the two parities, a RAID 6 unit can tolerate two hard drives failing simultaneously. This also means that a RAID 6 unit may be in two different states at the same time. For example, one sub-unit can be degraded, while another may be rebuilding, or one sub-unit may be initializing, while another is verifying.

RAID 6 requires a minimum of five drives. Performance and storage efficiency also increase as the number of drives increase.

12

3ware Serial ATA RAID Controller CLI Guide

Page 18
Image 18
AMCC 9590SE, 9550SX, 9500S, 9650SE manual RAID 5 Configuration Example