Installation

PARTITION

1 2 3 4

5 6 7 8

9

10

11 12

MII connection

 

LINK/RECEIVE

 

100BASE-TX PORTS

AsantéFAST 100 Hub

must be fibre

 

Repeater/Hub — UPLINK Port

 

 

(2km max length)

 

 

 

 

 

 

 

 

 

 

 

from MII port

from port 16 (Uplink)

 

 

 

 

 

 

on rear panel

 

 

 

 

 

 

 

MII 1

MII 2

Power

100Mbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FDP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

straight-through cable

(100m max. length)

 

 

 

Switched 10/100Mbps Ports

 

 

 

 

 

 

 

 

 

 

2

4

6

8

10

12

14

16

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Console

 

 

 

Port 16 in Uplink mode can

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

Uplink

 

 

 

 

be connected to hub using

1

3

5

7

9

11

13

15

Uplink

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

straight-through cable

 

 

 

 

 

 

 

 

 

 

 

 

 

(100m max. length)

 

 

 

 

straight-through cable

 

1

2

3

4

5 6 7 8

9 10 11 12

 

 

 

 

(100m max. length)

 

 

PARTITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK/RECEIVE

100BASE-TX PORTS

AsantéFAST 100 Hub

cross-over cable

(100m max. length)

straight-through cable

(100m max. length)

PARTITION

 

 

AsantéFAST 100 Hub

LINK/RECEIVE

100BASE-TX PORTS

Repeater/Hub — Standard Port

100Base-TX

Server

Network

Printer Station

Repeater/Hub — STANDARD Port

1

2

3

4

5

6

7

8

9

10

11

12

PARTITION

 

 

 

 

 

 

 

 

 

 

 

 

100BASE-TX PORTS

AsantéFAST 100 Hub

LINK/RECEIVE

 

Repeater/Hub — UPLINK Port

straight-through cable

(100m max. length)

Configuring for Management

BootP Configuration

Figure 2-2 IntraSwitch Cabling Scenarios

ΔNote: Pressing the Uplink switch toggles the usage of port 16 from normal to uplink or vice versa.This uplink feature is available only for regular RJ-45 port, and not for MII ports.When port 16 is used for uplink, the connection between port 16 to standard hub is straight- through cable.

To use the IntraSwitch as a managed switch, it must be configured with an IP address.This can be accomplished in one of two ways:

automatically using BootP (default)

manually via the unit’s Console port

The IntraSwitch is shipped with BootP support. BootP allows the IntraSwitch to be automatically configured with an IP

Page 2-8

Page 33
Image 33
Asante Technologies 6200 manual Configuring for Management, BootP Configuration