Console Configuration

Configuring for Management

address when it is connected to the network and is powered on, if your network contains a BootP server configured with available, valid IP addresses.

Important! BootP configuration only works if the IntraSwitch does not have an IP address assigned to it.

1

Make sure your network has a BootP server con-

 

figured with a valid IP address entry for the

 

IntraSwitch.

2

When the IntraSwitch is connected to the net-

 

work and is powered on, it automatically trans-

 

mits a BootP request across the network (up to

 

10times) until it receives a valid IP address from

 

the BootP server.

3

After an IP address is received, the IntraSwitch

 

can be managed via in-band access. See Chapter

4 for more information.

To verify that a valid IP address was received, use a tool such as Ping1 to try and access the IntraSwitch; if you can access the IntraSwitch, it is properly configured with an IP address.

See “Bootstrap Configuration” in Chapter 5 for more information on using BootP.

To manually configure the IntraSwitch with an IP address via its Console port, use a VT100 terminal or emulator (such as Hyper Terminal, ProComm, or ZTerm) running on a workstation or personal computer to connect to the switch’s Local Manage- ment Interface.

1.Ping is an application that can be used to test whether a remote device is properly connected to a network.