Baldor BXII installation manual Connector locations - front panel

Models: BXII

1 88
Download 88 pages 52.21 Kb
Page 18
Image 18
4.3 Connector locations - front panel

4.3 Connector locations - front panel

X1 Digital Inputs 8-15

1

DIN8

2

DIN9

3

DIN10

4

DIN11

5

DIN12

6DIN13

7DIN14

8

DIN15

9

CREF

10

Shield

X3 Analog Inputs

1

AIN0

2

AIN1

3AIN2

4

AIN3

5

AIN4

6

AIN5

7

AIN6

8

AIN7

9

AGND

10

Shield

X5 Relay & User Power

1 Relay COM

2 Relay NC

3 Relay NO

4 Relay COM

5 USR V+

6USR V+

7CREF

8

CREF

9

CGND

10

CGND

X6 Interrupts

1

FASTIN0

2

Shield

3CREF

4

FASTIN1

5

Shield

6

CREF

7

FASTIN2

8

Shield

9

CREF

10

FASTIN3

X8 Power

1

+24V

2

0V

3

Shield

4

+5V out

5

GND

6

+12V out

7GND

8

-12V out

Tightening torque for terminal block

9

Shield

10

Shield

connections is 0.25Nm (2.2 lb-in)

X2 Digital Inputs 0-7

1DIN0

2DIN1

3DIN2

4DIN3

5DIN4

6DIN5

7DIN6

8DIN7

9 CREF

10 Shield

X4 Digital Outputs 0-7

1DOUT0

2DOUT1

3DOUT2

4DOUT3

5DOUT4

6DOUT5

7DOUT6

8DOUT7

9 USR V+

10 CGND

X7 Demands

1AOUT0

2AGND

3AOUT1

4AGND

5AOUT2

6AGND

7AOUT3

8AGND

9 AGND

10 Shield

X9 Encoder 0

X10 Encoder 1

X11 Encoder 2

X12 Encoder 3

X13 Aux Encoder

1CHA+

2CHB+

3CHZ+

4(NC)

5DGND

6CHA-

7CHB-

8CHZ-

9+5V out

4-2 Input / Output

MN1904

Page 18