Baldor BXII Relay output, Encoder interfaces, CAN interfaces, Digital outputs, Description, Unit

Models: BXII

1 88
Download 88 pages 52.21 Kb
Page 77
Image 77
7.1.6 Digital outputs (X4)

7.1.6 Digital outputs (X4)

 

 

 

Description

Unit

Value

 

 

 

 

 

Output current

mA

50

 

(maximum continuous, each output)

 

 

 

 

 

 

 

Update interval

 

Immediate

 

 

 

 

7.1.7 Relay output (X5)

 

 

 

Description

Unit

Value

 

 

 

 

 

Contacts

 

Normally closed

 

 

 

 

 

Contact rating (resistive)

 

1A @ 24VDC

 

 

 

or

 

 

 

0.5A @ 120VAC

 

 

 

 

 

Maximum carrying current

A

2

 

 

 

 

 

Maximum switching power

 

60VA, 24W

 

 

 

 

 

Maximum switching voltage

 

125VAC, 60VDC

 

 

 

 

 

Maximum switching current

A

1

 

 

 

 

 

Contact resistance (maximum)

100

 

 

 

 

 

Update interval

 

Immediate

 

 

 

 

7.1.8 Encoder interfaces (X9 - X13)

 

 

 

Description

Unit

Value

 

 

 

 

 

Encoder input

 

A/B Differential, Z index

 

 

 

 

 

Maximum input frequency

MHz

1.87

 

 

 

 

 

Output power supply to encoders (total)

 

5V, 650mA max.

 

 

 

 

 

Maximum recommended cable length

 

30.5m (100ft)

 

 

 

 

7.1.9 CAN interfaces (X16 & X17)

Description

Unit

Value

 

 

 

Channels

 

CANopen, Baldor CAN

 

 

 

Bit rate

Kbit/s

10, 20, 50, 100, 125, 250, 500,

 

 

800, 1000

 

 

 

MN1904

Specifications 7-3

Page 77
Image 77
Baldor BXII Relay output, Encoder interfaces, CAN interfaces, Digital outputs, Description, Unit, Output current