Baldor BXII Analog outputs Demands, 7.1.4, 7.1.5, Digital inputs Interrupts, Description

Models: BXII

1 88
Download 88 pages 52.21 Kb
Page 76
Image 76
7.1.3 Analog outputs (Demands - X7)

7.1.3 Analog outputs (Demands - X7)

 

Description

Unit

Value

 

 

 

 

 

Type

 

Bipolar

 

 

 

 

 

Output voltage range

VDC

±10

 

 

 

 

 

Output current (max)

mA

1

 

 

 

 

 

Output DAC resolution

bits

14

 

 

 

(includes sign bit)

 

 

 

 

 

Equivalent resolution

mV

±1.22

 

 

 

 

 

Update interval

 

Immediate

 

 

 

 

7.1.4

Digital inputs (X1 & X2)

 

 

 

 

 

 

 

Description

Unit

Value

 

 

 

 

 

Type

VDC

Opto-isolated, AC inputs

 

 

 

 

 

Input voltage (Active high)

VDC

 

 

Nominal

 

24

 

Minimum

 

12

 

 

 

 

 

Input voltage (Active low)

VDC

 

 

Nominal

 

0

 

Maximum

 

2

 

 

 

 

 

Input current (approximate, per input)

mA

11

 

 

 

 

 

Sampling interval

ms

1

 

 

 

 

7.1.5

Digital inputs (Interrupts) (X6)

 

 

 

 

 

 

 

Description

Unit

Value

 

 

 

 

 

Type

VDC

Non-isolated, AC inputs

 

 

 

 

 

Input voltage (Active high)

VDC

 

 

Nominal

 

24

 

Minimum

 

12

 

 

 

 

 

Input voltage (Active low)

VDC

 

 

Nominal

 

0

 

Maximum

 

2

 

 

 

 

 

Input current (approximate, per input)

mA

9

 

 

 

 

7-2 Specifications

MN1904

Page 76
Image 76
Baldor BXII installation manual Analog outputs Demands, 7.1.4, 7.1.5, Digital inputs Interrupts, Description