Baldor BXII installation manual Relay and user power, 4-14Input / Output, MN1904

Models: BXII

1 88
Download 88 pages 52.21 Kb
Page 30
Image 30
4.7.3 Relay and user power - X5

4.7.3 Relay and user power - X5

Location

Connector X5

 

 

(Mating connector: Weidmüller BL 3.5/10, 3.5mm pitch)

 

 

 

Pin

Name

Description

 

 

 

1

Relay COM

Common relay connection

 

 

 

2

Relay NC

Normally closed relay connection

 

 

 

3

Relay NO

Normally open relay connection

 

 

 

4

Relay COM

Common relay connection

 

 

 

5

USR V+

Digital output customer power supply

 

 

 

6

USR V+

Digital output customer power supply

 

 

 

7

CREF

Digital input common connection

 

 

 

8

CREF

Digital input common connection

 

 

 

9

CGND

Digital output customer power supply ground

 

 

 

10

CGND

Digital output customer power supply ground

 

 

 

Description

Connection point for the digital outputs’ customer power supply and the relay contacts. Relay rated at 1A, 24VDC

The relay and user power connector X5 provides a connection point for the internal relay, the customer power supply used to power the digital outputs, and the digital input’s common connection. Power connections are assigned two pins to provide increased wiring capacity. The USR V+ and CGND connections on pins 5/6 and 9/10 are connected internally to the USR V+ and CGND pins on connector X4 - see section 4.6.4.

The relay outputs are isolated from any internal circuits in the NextMove BXII. The relay is controlled by a latch, which is cleared when the NextMove BXII resets. Reset can occur due to power-down, a watchdog error or when deliberately caused by the host PC. In normal operation the relay is energized and the Relay NC contact is connected to Relay COM. In the event of an error or power loss, the relay is de-energized and the Relay NO contact is connected to Relay COM.

The relay can be configured as a global error output using the Mint keyword

GLOBALERROROUTPUT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NextMove BXII

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mint

Relay NC

Pin 2

Relay NO

Pin 3

Relay COM Pin 1

Figure 8 - Relay connections

4-14 Input / Output

MN1904

Page 30
Image 30