4.6.4 Digital outputs - X4

4.6.4 Digital outputs - X4

1

10

Location

Connector X4

 

 

(Mating connector: Weidmüller BL 3.5/10, 3.5mm pitch)

 

 

 

Pin

Name

Mint keyword / description

 

 

 

1

DOUT0

OUTX.0

 

 

 

2

DOUT1

OUTX.1

 

 

 

3

DOUT2

OUTX.2

 

 

 

4

DOUT3

OUTX.3

 

 

 

5

DOUT4

OUTX.4

 

 

 

6

DOUT5

OUTX.5

 

 

 

7

DOUT6

OUTX.6

 

 

 

8

DOUT7

OUTX.7

 

 

 

9

USR V+

Customer power supply V+

 

 

 

10

CGND

Customer power supply ground

 

 

 

Description

Eight general purpose optically isolated digital outputs. Output current: 50mA maximum (continuous) each output Update interval: Immediate

Each optically isolated output is designed to source current from the customer supplied

12-24V supply (USR V+) as shown in Figure 6. The outputs can be written to directly using the Mint keyword OUTX (for example OUTX.2=1).

The sense of the outputs can be configured in WorkBench v5, and their states are displayed in the Spy window. The use of shielded cable is recommended.

NextMove BXII

OUTX.x Figure 6 - Digital output circuitManual background

UDN2987 Output module

TLP121

Figure 6 - Digital output circuit

USR V+

DOUTx

Output load

CGND

The USR V+ and CGND connections on pins 9 and 10 are connected internally to the USR V+ and CGND pins on connector X5. See section 4.7.3.