Gateway Address

DS62-Network, DS62-MD4 Network/Modem Host Module

Select 2) to enter the Subnet Mask followed by <cr>. Failure to enter the address in the decimal form causes the DS to display the following until it is entered correctly. Default Subnet Mask is 0.0.0.0.

Enter Subnet Mask in dotted decimal form :

Gateway Address

The Gateway is the address of a router to connect to other parts of a network. The Gateway address consists of four bytes, each byte ranging from 0 to 255. If your network uses gateways, this parameter must be programmed before the DS can be accessed through the network.

Select 3) to enter the Gateway address. Failure to enter the address in the decimal form causes the DS to display the following until it is entered correctly. Default Gateway address is 0.0.0.0.

Enter Gateway address in dotted decimal form :

Inactivity Timeout

This option enables the DS to disconnect after the programmed amount of time, if there is no activity. Default is 0 (DISABLED). The enabling input can be from 1 to 120 minutes.

Connection Inactivity Timeout is 0 minutes

Enter timeout, in minutes (<=120, 0 to disable) :

Enter 0 to disable or a number between 1 and 120 (inclusive) to set the timeout.

Carriage Return Translation

This option determines what the telnet processor will do with the line-feeds and nulls after a carriage return is sent. Enable tells the DS Telnet processor to strip line feeds or nulls Translation after the carriage returns. Disable allows the characters to pass through. Default is “DISABLED”.

Carriage Return Translation is.... Enabled

Enable ? (Y/N), CR for no change) :

Break Length

Users may configure the DS for a break length of 1 - 1000 milliseconds. In a Telnet session with the DS through the serial port of a DS74, send a Telnet break command (0xF3) to the DS, the serial port will send a break signal of the programmed duration. Default is 350 milliseconds.

Break Length is (msec)

350

Enter break length, in milliseconds (<=10000, 0 to disable) :