DS62 and DS62-MD4 Reset procedure

DS62-Network, DS62-MD4 Network/Modem Host Module

e.From your PC create a terminal session to the serial port. Default setting is 9600, 8, 1, no parity, no flow.

f.Type several random characters to see them echoed in the telnet/modem session.

g.Select the telnet/modem session and type several random characters to see them echoed in the PC serial session.

h.This verifies the Chassis, Host module, and the I/O port is working.

i.Move pc cable to next DS74 port and repeat steps (c-h).

If a DS74 module appears not to be working, move the module to a different slot and retest.

DS62 and DS62-MD4 Reset procedure

Figure 1

DS62-MD4 similar to DS62

Caution: This procedure will reset configuration to factory default.

DS62/DS62-MD4:

1.Remove the module from the chassis (with the unit powered down).

2.Hold the module with the chip side up and the faceplate towards you.

3.Locate jumper JMP5 approximate center of circuit board.

4.Move the jumper from pins 1 and 2 to pins 2 and 3.

5.Put the module back in the chassis and power up for 15 seconds.

6.Take the module back out and replace the jumper to the original position. The module is now reset to factory default.

Note: If the module appears not to have reset or opening menu has random characters in it, perform the reset procedure again except increase the reset time from 15 to 30 seconds.