Black Box ET0100A, ET1000A, ET0010A Powering on the ET10000A, Safety Guidelines, ET10000A Cabling

Models: ET10000A ET0100A ET0010A ET1000A

1 88
Download 88 pages 24.35 Kb
Page 52
Image 52
Figure 39 ET10000A Cabling

Installation

Figure 39 ET10000A Cabling

Powering on the ET10000ASafety GuidelinesManual background NOTE

The Aux ports, and USB and Gigabit management ports are not enabled in this release.

Powering on the ET10000A

This section lists important safety guidelines for the ET10000A power modules, and describes how to safely apply power to the appliance.

Safety Guidelines

Review the following guidelines prior to powering up the ET10000A:

The ET10000A has two power supplies. We recommend that you connect the power cords to separate live circuits to provide redundancy in the case of a power outage on one of the circuits.

When manually cycling the power, remove power on both circuits, wait five seconds, and then reapply power on both circuits.

When equipped with DC power supplies, the ET10000A is intended for connection to DC mains. It should be installed only in a restricted access location. Use only the following fuse type for each DC power module input circuit:

250 Vac/125Vdc, 25A, Type=Slow Blow, Time Lag