Troubleshooting
.
Table 29 ET0010A Operational Codes
Code | Description |
All status LEDs off | Up and operational. |
2, 3, 4 | The ET0010A is in a shutdown state. |
|
|
Diagnostic Codes: ET0100A, ET1000A and ET10000A
The
When the appliance powers up, all LEDs illuminate. The Alarm LED illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning. As the ETEP cycles through its
If the ETEP fails to boot properly the diagnostic code display indicates the number of the last test that completed successfully, and a message describing the failure is displayed on the terminal. In addition, the Alarm light illuminates if diagnostic tests
After the ETEP boots up, the diagnostic display reflects the operational state of the appliance. .
ETEP Self-Tests
Code
88
01
02
03
04
05
06
07
00
Description
Bootflash CRC test.
DRAM test #1.
Initialize IO devices. DRAM test #2.
Initialize compact flash. Complete bootloader initialization. Download operating system.
Start operating system, IPSec dataplane code, and management and control software.
Up and operational.
Table 30 ETEP Operational Codes
Code | Description |
00 | Up and operational. |
rb | The ETEP is in a reboot required state. |
AL | An alarm condition or error condition has been reported. |
dL | The ETEP is downloading new software. |
rS | The ETEP has issued a restart/reboot command. |
– – | The ETEP is in a shutdown state. |
|
|
76 | ETEP Installation Guide |