APPENDIX 4 SYSTEM MODE | |
| A4.4 |
|
|
A4.4 | While in a Pause condition press and hold the [RESTART] key until |
Test (Cont.) | “<0>RESET”!5(6(7appears in the display. |
| Then, press!',the$*[FEED]9[[key, and “<1>DIAG. Vx.x” message appears. |
Ribbon type selection
Press the [PAUSE] key. The ribbon type can be selected:
“NO RIBBON” (Direct Thermal Paper), “TRANS.” (Transmissive ribbon), or “NO TRANS.” (Non transmissive ribbon).
After selecting the ribbon type, press the [PAUSE] key to confirm and go to Maintenance counter and Parameter settings print out.
NOTE:
When using a ribbon, be sure to select “TRANS” or “NO TRANS.”. When using direct thermal media, be sure to select “NO RIBBON”.
125,%%21
[RESTART]
5,%%211275$16
[FEED]
Direct thermal paper
Transmissive ribbon
Non transmissive ribbon
Maintenance counter/parameter settings print out
NOTE:
See Section A4.8.2 for a Maintenance Counter and Parameter Settings print sample and a detailed description for each item.
NOTES:
1.If an error occurs, an error message appears, and the printer stops printing. After clearing the error, press the [PAUSE] key to return to “<1>DIAG.”. The printer does not resume printing automatically.
2.See Section A4.8.1 for
The printer will print out the Maintenance Counter and Parameter Settings. Press the [PAUSE] key to start.
&+(&0$,17(1.,1*$1&(35,17&217
The printer starts printing out the Maintenance Counter & Parameter Settings.
After printing is completed, the display returns to “<1>DIAG. Vx.x”.
Self-Diagnostic$872',$*1267,&Test and the result print out
After the Maintenance Counter and Parameter Settings print out has been completed,&+(&.,1*the display35,17returns to “<1>DIAG. Vx.x”. Press the [PAUSE] key twice then [FEED] key once.
The
The printer starts the
After printing is completed, the display returns to “<1>DIAG. Vx.x”.
A4- 4