Installation
Electrical Connection
Before making any electrical connections to this unit, check that the power supply is adequate for the voltage, amperage, and phase requirements stated on the rating plate.
NOTE: The rating plate is located on the control box.
A wiring diagram accompanies this manual and is also attached inside the control box.
U.S. and Canadian installations
The MT3855 requires a 15 Amp, 60HZ, 1Φ,
Single phase units MUST NOT be connected to the high leg of a three phase system. The high leg refers to a potential of 240 volts between one phase and neutral. The remaining two legs have a potential of 120 volts between each phase and neutral.
Connect the four wires at the connections box lo- cated on the lower left side of the control panel
1.Connect the two black wires to the
2.Connect the white wire to the system neutral.
3.Connect the green wire to the system ground.
Australia and general export installations
The MT3855 requires a 15 Amp, 50Hz, 1Φ,
WARNING!!
Incorrect single phase wiring will result in extensive damage to electrical compo- nents and possible fire in the control box.
| L1 |
|
|
| |
| N | 120 |
| ||
Supply | L2 | 120 | Oven | ||
|
U.S. and Canadian Installations
| L1 |
|
|
Supply | N | Oven | |
|
|
General Export Installations
Figure 15
THE BLODGETT OVEN COMPANY CANNOT AS- SUME RESPONSIBILITY FOR LOSS OR DAMAGE SUFFERED AS A RESULT OF IMPROPER INSTAL- LATION.
14